6 Troubleshooting
International English
MICROMASTER 440 Operating instructions
68
6SE6400-5CA00-0BP0
Warnings
♦
Repairs on equipment may only be carried out by
Siemens Service
, by repair
centers
authorized by Siemens
or by qualified personnel who are thoroughly
acquainted with all the warnings and operating procedures contained in this
manual.
♦
Any defective parts or components must be replaced using parts contained in
the relevant spare parts list.
♦
Disconnect the power supply before opening the equipment for access
6.1
Troubleshooting with the Status Display Panel
Table 6-1 explains the meaning of the various states of the LEDs on the Status
Display Panel (SDP).
Table 6-1
Inverter conditions indicated by the LEDs on the SDP
LEDs
Green
Yellow
Priority
Display
Inverter Status Definitions
OFF
OFF
1
Mains not present
OFF
ON
8
Inverter fault – other than those listed below
ON
OFF
13
Inverter running
ON
ON
14
Ready to run – standby
OFF
Flashing – R1
4
Fault – Overcurrent
Flashing – R1
OFF
5
Fault – Overvoltage
Flashing – R1
ON
7
Fault – Motor Overtemperature
ON
Flashing – R1
8
Fault – Inverter Overtemperature
Flashing – R1
Flashing – R1
9
Warning Current Limit (both LEDs flashing at the
same time)
Flashing – R1
Flashing – R1
11
Other warning (both LEDs alternate flashing)
Flashing – R1
Flashing – R2
6/10
Undervoltage trip/Undervoltage warning
Flashing – R2
Flashing – R1
12
Inverter is not in ready state – display >0
Flashing – R2
Flashing – R2
2
ROM failure (both LEDs flashing at the same time)
Flashing – R2
Flashing – R2
3
RAM failure (both LEDs alternate flashing)
R1 – On time 900 milliseconds
R2 – On time 300 milliseconds