Motor Components (Options)
Holding brake
1FK7 Synchronous Motors
4-14
Configuration Manual (PFK7), 10/2005 Edition, 6SN1197-0AD06-0BP1
4.3.4
Technical data of the holding brake
Holding torque M4
The holding torque M
4
is the minimum brake torque in steady-state operation (when the motor
is at a standstill).
For motors with forced cooling or water cooling, the holding torque of the brake can be less
than the motor stall torque.
Note
Motors with or without holding brake cannot be subsequently retrofitted!
Motors with holding brake are longer by the mounted space required (refer to the dimension
drawing).
Table 4-13:
Technical data of the holding brakes used for 1FK7 motors
Motor type
Brake type
Holding
torque
M
4
1)
DC current
Opening time
with varistor
Closing time
with varistor
Highest
switching
energy
[Nm]
[A]
[ms]
[ms]
[J]
1FK7 CT
Permanent-magnet brakes
1FK7022
EBD 0.11 BN
1
0.3
30
20
8
1FK703
EBD 0.13 BN
1.1
0.4
50
30
17
1FK704
EBD 0.3 BV
3.2
0.6
70
30
74
1FK706
EBD 0.8 BK
13
0.8
100
50
400
1FK7080
EBD 1.5 BN
10
0.8
100
50
400
1FK7083
1FK7100
EBD 2 BY
22
0.9
200
60
1400
1FK7101
1FK7103
1FK7105
EBD 3.5 BV
41
1.0
300
70
3000
1FK7 HD
Spring-operated brakes
1FK7033
1EB 14–30
1.3
0.5
100
40
14
1FK704
1EB 20–40
4
0.6
150
50
96
1FK706
1EB 28–60
12
0.8
150
50
230
1FK708
1EB 35–80
22
1.2
200
60
700
1)
Standardized acc. to VDE 0580 with varistor circuit
Содержание MASTERDRIVES MC 1FK7
Страница 1: ... VLPRGULYH PDVWHUGULYHV RQILJXUDWLRQ 0DQXDO GLWLRQ 6 QFKURQRXV 0RWRUV 6 02 5 9 0 67 5 5 9 6 0 ...
Страница 2: ......
Страница 10: ...Foreword 1FK7 Synchronous Motors viii Configuration Manual PFK7 10 2005 Edition 6SN1197 0AD06 0BP1 ...
Страница 162: ...Index I 2 1FK7 Synchronous Motors Configuration Manual PFK7 10 2005 Edition 6SN1197 0AD06 0BP1 ...
Страница 164: ......
Страница 165: ......