AT command interface
Version 8 dated 15.03.00
36
Siemens Information and Communication Products
ATDI
Mobile originated call to dialable ISDN number <n>
Execute command
ATDI<n>[;]
Response
TA attempts to set up an outgoing call to ISDN number.
Note:
this command may be aborted generally by receiving a character during execution. This com-
mand cannot be aborted in some connection setup states, such as handshaking.
If no dialtone and (parameter setting X=2 or X=4)
NO DIALTONE
If busy and (parameter setting X=3 or X=4)
BUSY
If a connection cannot be set up
NO CARRIER
If successfully connected and non-voice call
CONNECT<text>
Note:
<text> only if parameter setting X>0
TA switches to data state.
When TA returns to command mode after call release
OK
If successfully connected and voice call
OK
Parameter
<n>
[+]<d> phone number
string with maximum length of 20 characters
+
international dialling format
<d>
ISDN number
string of digits: +,0-9, A, B, C
<;>
voice call
Reference
Siemens
Note