![Siemens LOHER CHEMSTAR 1PS2 Скачать руководство пользователя страница 119](http://html.mh-extra.com/html/siemens/loher-chemstar-1ps2/loher-chemstar-1ps2_operating-instructions-and-installation_378987119.webp)
Technical data and drawings
B
Bolt locking devices
● Refit nuts or bolts that are mounted together with locking, resilient, and/or force-distributing
elements with identical, fully-functional elements when re-assembling. Always renew keyed
elements.
● When screwing together threads secured with a liquid adhesive, use a suitable medium
such as Loctite 243.
Tightening torques
The bolted connections with metal contact surfaces, such as end shields, bearing cartridge
parts, terminal box parts bolted onto the stator frame, should be tightened to the following
torques, depending on the thread size:
Table B-1
Tightening torques for bolted connections with a tolerance of ±10%.
Case
M4
M5
M6
M8 M10 M12 M16 M20 M24 M30 M36 M42 M48 M56
A
1.2
2.5
4
8
13
20
40
52
80
150
-
-
-
-
Nm
B
1.3
2.6
4.5
11
22
38
92
180 310 620 108
0
170
0
260
0
420
0
Nm
C
3
5
8
20
40
70
170 340 600 120
0
200
0
310
0
470
0
750
0
Nm
Applications
The above-mentioned tightening torques apply for the following applications:
● Case A
Applies to electrical connections in which the permissible torque is normally limited by the
bolt materials and/or the current carrying capacity of the insulators, with the exception of
the busbar connections in case B.
● Case B
Applies to bolts screwed into components made from materials with lower property class
(e. g. aluminum) and to bolts with property class 8.8 according to ISO 898-1.
● Case C
Applies to bolts with property class 8.8 or A4-70 according to ISO 898-1, however only to
bolts screwed into components made from materials with higher property class, e.g. cast
iron, steel or cast steel.
Note
Non-standard tightening torques
Different tightening torques for electrical connections and bolted connections for parts with
flat seals or insulating parts are specified in the relevant sections and drawings.
LOHER CHEMSTAR 1PS2
Operating Instructions 08/2016
119
Содержание LOHER CHEMSTAR 1PS2
Страница 2: ...04 08 2016 11 45 V3 00 ...
Страница 12: ...Introduction 1 1 About these instructions LOHER CHEMSTAR 1PS2 12 Operating Instructions 08 2016 ...
Страница 38: ...Preparations for use 4 13 Transport and storage LOHER CHEMSTAR 1PS2 38 Operating Instructions 08 2016 ...
Страница 64: ...Electrical connection 6 2 Connecting LOHER CHEMSTAR 1PS2 64 Operating Instructions 08 2016 ...
Страница 74: ...Start up 7 8 Test run LOHER CHEMSTAR 1PS2 74 Operating Instructions 08 2016 ...
Страница 84: ...Operation 8 11 faults LOHER CHEMSTAR 1PS2 84 Operating Instructions 08 2016 ...
Страница 102: ...Maintenance 9 2 Corrective Maintenance LOHER CHEMSTAR 1PS2 102 Operating Instructions 08 2016 ...
Страница 118: ...Service and Support LOHER CHEMSTAR 1PS2 118 Operating Instructions 08 2016 ...
Страница 120: ...Technical data and drawings LOHER CHEMSTAR 1PS2 120 Operating Instructions 08 2016 ...
Страница 121: ...Quality documents C C 1 EC Declaration of Conformity LOHER CHEMSTAR 1PS2 Operating Instructions 08 2016 121 ...
Страница 122: ...Quality documents C 1 EC Declaration of Conformity LOHER CHEMSTAR 1PS2 122 Operating Instructions 08 2016 ...
Страница 138: ...Quality documents C 2 IECEx certificate LOHER CHEMSTAR 1PS2 138 Operating Instructions 08 2016 ...
Страница 142: ...Index LOHER CHEMSTAR 1PS2 142 Operating Instructions 08 2016 ...
Страница 143: ...AD EC Declaration of Conformity U161 ...
Страница 144: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...