16

15.8 Instructions for the air extraction mode

For air extraction mode, a one-way flap should be in-
stalled.

Notes

¡

If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.

¡

If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.

15.9 Installation

Checking the ceiling

1.

Check whether the ceiling is horizontal and ad-
equately load-bearing.

2.

Drill the hole depth in accordance with the length of
the screws.
The wall plugs must have a secure grip.

3.

The screws and wall plugs enclosed are only suit-
able for use with solid brickwork.
Suitable fasteners must be used for other structures,
e.g. plasterboard, aerated concrete, Poroton blocks,
masonry bricks.

4.

The maximum weight of the appliance is 50 kg.

Fitting the upper support frame

1. Note: 

The height of the support frame can be adjus-

ted in 20 mm increments.
Before installation, specify the total height of the
support frame and mark the screw holes.

2.

On the ceiling, mark the centre point of the appli-
ance.

3.

Use the enclosed template to mark the positions for
the screws on the ceiling.

4.

Drill four holes with a diameter of 8 mm to a depth
of 80 mm for fastening the appliance and push in
the wall plugs flush with the wall.

5.

Attach the upper part of the support frame to the
ceiling using 4 screws.
– Ensure that the support frame is in the correct

position.

– The middle bracket defines the preferred side

and must be facing the hob's control.

Installing the lower support frame

Attach the upper and lower section of the support
frame at the specified total height using 10 screws.

– Ensure that the lower support frame is in the cor-

rect position.

– The open side must be facing the hob's control.

Tip: 

If you undo the fastening screws, you can retroact-

ively realign the support frame.

Installing the appliance

1.

Hook the appliance from below into the support
frame.
Ensure that the power cord is not trapped.

Содержание LF91BUV50

Страница 1: ... LF91BUV50B LF91BUV55 en User manual and installation instructions Register your product on My Siemens and discover exclusive ser vices and offers siemens home bsh group com welcome The future moving in Siemens Home Appliances ...

Страница 2: ... domestic environment Up to an altitude of max 2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by children aged 8 or over and by people who have reduced physical sensory or mental abilities or inad equate experience and or knowledge provided that they are supervised or have been instructed on how to use the appliance s...

Страница 3: ...cted operation is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance without a grease filter Clean the grease filters regularly Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a solid fuel heating appliance e g wood or coa...

Страница 4: ...fac turer the manufacturer s Customer Service or a similarly qualified person in order to prevent any risk An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure clean ers to clean the appliance WARNING Risk of explosion Highly caustic alkaline or highly acidic clean ing agents in conjuncti...

Страница 5: ...lighting if it is no longer required When the lighting is switched off it does not con sume any energy Clean or replace the filters at regular intervals The effectiveness of the filter is retained Put the cooking lid on The cooking vapours and condensation are re duced Only use the additional functions if required Switching off additional functions reduces power consumption 4 Operating modes You c...

Страница 6: ...itching on intensive mode If particularly strong odours or vapours develop you can use intensive mode Press or slide your finger to the right over the set tings area until appears on the display a After approx 6 minutes the appliance automatically switches to fan setting 3 6 5 Switching off intensive mode Slide your finger to the left over the settings area 6 6 Switching on the boost function The ...

Страница 7: ...elease and to save the setting 6 15 Switching on the lighting The lighting can be switched on and off independently of the ventilation system Press 6 16 Setting the brightness Press and hold until the required brightness is reached 6 17 Switching on the audible signal Requirement The appliance is switched off Press and hold and at the same time for ap prox three seconds a appears on the display 6 ...

Страница 8: ...o the Home Connect server and if Remote Diagnostics is available in the country in which you are using the appliance Tip For further information and details about the avail ability of Remote Diagnostics in your country please visit the service support section of your local website www home connect com 7 5 Data protection Please see the information on data protection The first time your appliance i...

Страница 9: ...do not use commer cial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods WARNING Risk of electric shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure cleaners to clean the appliance WARNING Risk of burns The appliance becomes hot...

Страница 10: ... The grease filters have been removed 1 Observe the information regarding the cleaning agents 2 Place the grease filters loosely into the dishwasher Do not clean heavily soiled grease filters with utensils Use special grease solvent for stubborn dirt You can obtain grease solvents from after sales service or the online shop 3 Start the dishwasher Select a temperature of no more than 70 C 4 Allow t...

Страница 11: ...d elec trical and electronic appliances waste electrical and electronic equip ment WEEE The guideline determines the frame work for the return and recycling of used appliances as applicable throughout the EU 12 Customer Service Function relevant genuine spare parts according to the corresponding Ecodesign Order can be obtained from Customer Service for a period of at least 10 years from the date o...

Страница 12: ...ent LZ56200 Long Life odour filter need for replacement LZ00XXP00 14 Declaration of Conformity BSH Hausgeräte GmbH hereby declares that the appli ance with Home Connect functionality conforms to the basic requirements and other relevant provisions of Dir ective 2014 53 EU A detailed RED Declaration of Conformity can be found online at siemens home bsh group com among the ad ditional documents on t...

Страница 13: ... supply of air the air pressure falls below atmospheric pressure Toxic gases from the flue or the extraction shaft are sucked back into the living space Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as a room air dependent heat producing appli ance is being operated It is only possible to safely operate the ap pliance if the pr...

Страница 14: ... appliance and wall or high sided unit must be at least 50 mm The grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non remov able cover is present There must be no fly ing sparks WARNING Risk of injury Components inside th...

Страница 15: ...be possible to disconnect the appliance from the electricity supply The appliance must only be connected to a protective contact socket that has been correctly installed The mains plug for the mains power cable must be easily accessible after the appliance is installed If this is not possible an all pole isolating switch must be integrated into the permanent electrical in stallation according to t...

Страница 16: ...an be adjus ted in 20 mm increments Before installation specify the total height of the support frame and mark the screw holes 2 On the ceiling mark the centre point of the appli ance 3 Use the enclosed template to mark the positions for the screws on the ceiling 4 Drill four holes with a diameter of 8 mm to a depth of 80 mm for fastening the appliance and push in the wall plugs flush with the wal...

Страница 17: ...con nector 3 Seal the joints Installing the flue duct WARNING Risk of injury Components inside the appliance may have sharp edges Wear protective gloves WARNING Risk of electric shock Sharp edged components inside the appliance may damage the connecting cable Do not kink or trap the connecting cable 1 To separate the flue ducts remove the adhesive tape or the flue duct from the protective packagin...

Страница 18: ......

Страница 19: ......

Страница 20: ...nchen GERMANY siemens home bsh group com Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom Manufactured by BSH Hausgeräte GmbH under the trademark licence of Siemens AG ...

Отзывы: