en
Troubleshooting
12
2. Note:
The appliance frame is sensitive. Remove the
grease filter cartridges vertically. Do not pull the
grease filter cartridges over the appliance frame.
Remove the grease filter cartridges.
3.
Insert the grease filter into the grease filter cart-
ridges.
To avoid causing damage, do not bend the grease
filters.
4.
Carefully insert the grease filter cartridges.
5.
Press .
6.
a
The glass panel and the filter cartridges move
downwards.
a
The appliance flap closes and the appliance
switches off.
11 Troubleshooting
You can rectify minor faults on your appliance yourself. Read the troubleshooting information before contacting after-
sales service. This will avoid unnecessary costs.
WARNING ‒ Risk of injury!
Improper repairs are dangerous.
▶
Repairs to the appliance should only be carried out
by trained specialist staff.
▶
If the appliance is defective, call Customer Service.
WARNING ‒ Risk of electric shock!
Incorrect repairs are dangerous.
▶
Repairs to the appliance should only be carried out
by trained specialist staff.
▶
Only use genuine spare parts when repairing the
appliance.
▶
If the power cord of this appliance is damaged, it
must be replaced by trained specialist staff.
11.1 Malfunctions
Fault
Cause and troubleshooting
The appliance is not
working.
The mains plug of the power cord is not plugged in.
▶
Connect the appliance to the power supply.
The circuit breaker is faulty.
▶
Check the circuit breaker in the fuse box.
There has been a power cut.
▶
Check whether the lighting in your kitchen or other appliances are working.
The glass panel is not inserted correctly.
▶
Insert the glass panel carefully as far as it will go.
Liquid flows into the appliance.
▶
Pull out the mains plug or switch off the appliance at the circuit breaker in the fuse box.
▶
Empty the drip trays and remove the grease filters cartridges. →
▶
Dry all accessible places.
▶
Leave the appliance flap open and restart the appliance only after 48 hours.
▶
Insert the drip tray and the grease filters cartridges.
The glass panel is removed, and the appliance has been operated.
▶
Insert the glass panel and disconnect the appliance from the power supply for ap-
prox. one minute.