Test information
en
15
16 Test information
This information has been produced to facilitate the in-
spection of the appliance.
¡
Measured in accordance with EN 61591.
¡
The appliance is operated in its as-delivered condi-
tion.
¡
The fan box must be attached on the front of the ap-
pliance.
¡
Ensure that the filters do not move during the meas-
urement (by changing the appliance position to the
installation position).
¡
The ambient light is not a working light. The ambient
light in light colour red has been added to the FDE
value as a power consumer.
17 Installation instructions
Observe this information when installing the appliance.
17.1 Included with the appliance
After unpacking all parts, check for any damage in
transit and completeness of the delivery.
17.2 Appliance dimensions
You will find the dimensions of the appliance here
Observe the dimensions of the unit.
17.3 Secure installation
Follow these safety instructions when in-
stalling the appliance.
WARNING ‒ Risk of poisoning!
Risk of poisoning from flue gases being
drawn back in. Room-air-dependent heat-pro-
ducing appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and dis-
charge the exhaust gases into the open
through an exhaust gas system (e.g. a chim-
ney). With the extractor hood switched on, air
is extracted from the kitchen and the adjacent