\RXU
SURGXFW
RQOLQH

VLHPHQVKRPHEVKJURXSFRPZHOFRPH

[en]Instructions for installation and use 

Extractor hood 

Содержание LC97BCP50

Страница 1: ...5HJLVWHU RXU SURGXFW RQOLQH VLHPHQV KRPH EVK JURXS FRP ZHOFRPH en Instructions for installation and use Extractor hood ...

Страница 2: ......

Страница 3: ...ocation This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used...

Страница 4: ...weep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the grease filter may catch fire Regularly clean the grease filter Never operate the appliance without a grease filter Risk ...

Страница 5: ...Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while cooking to avoid condensation Condensate can produce corrosion damage Always replace faulty bulbs to prevent the remain...

Страница 6: ...speed in good time If the cooking steam has already spread around the kitchen the extractor hood will need to be operated for longer Switch off the extractor hood if you no longer require it Switch off the lighting if you no longer require it Clean and if required replace the filter at regular intervals in order to increase the effectiveness of the ventilation system and to prevent the risk of fir...

Страница 7: ...til 2 is shown on the display panel Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset time expires touch the A symbol to select the fan setting you require Boost function Switching on Touch the symbol Note After approximately 20 seconds the extractor hood automatically switches back to the f...

Страница 8: ...al will sound as an acknowledgement When the signal tone is activated will be lit Switching off Touch and hold the and symbols at the same time for approximately 3 seconds when the fan is switched off An audible signal will sound as an acknowledgement When the signal tone is deactivated will be lit 2Cleaning and maintenance Cleaningandmaintenance Warning Risk of burns The appliance becomes hot dur...

Страница 9: ...em thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Place the me...

Страница 10: ...rs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electricia...

Страница 11: ...models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory E no FD no After sales serviceO GB 0344 892 8999 Calls charged at local or mobile rate IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute Accessory narrow 260 mm Order number Starter set for air recirculation mode Easy chang...

Страница 12: ... that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty dep...

Страница 13: ...ncoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or...

Страница 14: ...m flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances If the exhaust air is to be conveyed into a non functioning smoke or exhaust gas flue you must obtain the consent of the heating engineer responsible If the exhaust air is conveyed through...

Страница 15: ...nstallation of the appliance If this is not possible an all pole isolating switch must be integrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The permanent electrical installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in ...

Страница 16: ...e appliance 1 First remove the protective foil from the back of the appliance and following installation remove the foil completely 2 When attaching the appliance ensure that it engages firmly with the brackets 3 Align the appliance horizontally by turning the brackets If required the appliance can be moved to the right or left 4 Firmly tighten the screws for the brackets When doing so hold the br...

Страница 17: ...g Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective foil from both flue ducts 3 Push one flue duct into the other Notes To prevent scratches lay paper over the edges of the lower flue duct to protect the surface Slots of the inner flue duct point downwards 4 Place flue duc...