background image

Extractor hood

LC67KEM60, LC87KEM60

en

User manual and installation instructions

Register your product on My Siemens and discover exclusive
services and offers.
siemens-home.bsh-group.com/welcome

The future moving in.

Siemens Home Appliances

Содержание LC67KEM60

Страница 1: ...7KEM60 LC87KEM60 en User manual and installation instructions Register your product on My Siemens and discover exclusive services and offers siemens home bsh group com welcome The future moving in Siemens Home Appliances ...

Страница 2: ...ectly at its installation location Only use this appliance For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up to an altitude of max 4000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group Avoid risks to children and vulnerable per sons This appliance may be used by children aged 8 or over and by peopl...

Страница 3: ...e e g wood or coal burning unless the heating appliance has a sealed non removable cover There must be no flying sparks Hot oil or grease ignites very quickly Always supervise hot oil and fat Never extinguish burning oil or fat with wa ter Switch off the cooking zone Extinguish flames carefully using a lid fire blanket or something similar When gas burners are in operation without any cookware pla...

Страница 4: ... with aluminium parts in the interior of the appliance may cause ex plosions Never use highly caustic alkaline or highly acidic cleaning agents In particular do not use commercial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods 2 Preventing material damage 2 1 General Follow these instructions when using the appliance ATTENTION Condensate may ...

Страница 5: ... ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conveyed through the external wall a tele scopic duct should be used 4 2 Air recirculation mode The air which is drawn in is cleaned by the grease fil ters and an odour filter and conveyed back into the room To bind odours in circulating air mode you must install an odour filter The dif ferent...

Страница 6: ...he appliance automatically switches to fan setting 3 7 5 Switching off intensive mode Press a Intensive mode is ended early 7 6 Switching on the lighting The lighting can be switched on or off independently of the ventilation Press 7 7 Switching off the lighting Switch off the lighting with 8 Cleaning and servicing To keep your appliance working efficiently for a long time it is important to clean...

Страница 7: ...ervice or the online shop 3 Use a brush to clean the grease filters 4 Rinse the grease filters thoroughly 5 Allow the grease filters to drain 8 10 Cleaning grease filters in the dishwasher The grease filters filter the grease from the cooking va pour Regularly cleaned grease filters guarantee a high level of grease removal WARNING Risk of fire Fatty deposits in the grease filters may catch fire Cl...

Страница 8: ...cluding after the manufac turer s warranty has expired Function relevant genuine spare parts according to the corresponding Ecodesign Order can be obtained from Customer Service for a period of at least 10 years from the date on which your appliance was placed on the market within the European Economic Area Note Under the terms of the manufacturer s warranty the use of Customer Service is free of ...

Страница 9: ...d 3 Dispose of the appliance in an environmentally friendly manner This appliance is labelled in accord ance with European Directive 2012 19 EU concerning used elec trical and electronic appliances waste electrical and electronic equip ment WEEE The guideline determines the frame work for the return and recycling of used appliances as applicable throughout the EU 13 Installation instructions Obser...

Страница 10: ...ing operated in exhaust air mode at the same time as a room air dependent heat produ cing appliance is being operated It is only possible to safely operate the appliance if the pressure in the room in which the heating appli ance is installed does not drop more than 4 Pa 0 04 mbar below atmospheric pressure This can be achieved whenever the air needed for com bustion is able to enter through openi...

Страница 11: ...ions of Overvoltage Cat egory III and according to the installation regula tions When installing the appliance check that the power cable is not trapped or damaged 13 6 Information on the installation situation Install this appliance on the kitchen wall 13 7 Instructions for the exhaust air pipe The appliance manufacturer does not provide any war ranty for faults attributable to the pipeline Use a...

Страница 12: ... use the right or left hole opening Fitting the flue duct 1 To separate the flue duct sections remove the ad hesive tape 2 Remove the protective foil from both flue duct sec tions 3 Note To prevent scratches lay paper over the edges of the outer flue duct section to protect the sur face The slots on the inner flue duct section should point downwards Push one flue duct section into the other 4 Inse...

Страница 13: ...Installation instructions en 13 2 Insert the brackets for the filter cover into the open ings on the appliance and lock into place 3 Remove the edge protection ...

Страница 14: ......

Страница 15: ......

Страница 16: ...hen GERMANY www siemens home bsh group com Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom Manufactured by BSH Hausgeräte GmbH under the trademark licence of Siemens AG ...

Отзывы: