background image

Extractor hood

LB.958.M, LB79585MGB

en

User manual and installation instructions

Register your product on My Siemens and discover exclusive ser-
vices and offers.
siemens-home.bsh-group.com/welcome

The future moving in.

Siemens Home Appliances

Содержание LB 958 M Series

Страница 1: ...58 M LB79585MGB en User manual and installation instructions Register your product on My Siemens and discover exclusive ser vices and offers siemens home bsh group com welcome The future moving in Siemens Home Appliances ...

Страница 2: ... children aged 8 or over and by people who have reduced physical sensory or mental abilities or inad equate experience and or knowledge provided that they are supervised or have been instructed on how to use the appliance safely and have understood the resulting dangers Children must not play with the appliance Children must not perform cleaning or user maintenance unless they are at least 15 year...

Страница 3: ... supervise hot oil and fat Never extinguish burning oil or fat with wa ter Switch off the cooking zone Extinguish flames carefully using a lid fire blanket or something similar When gas burners are in operation without any cookware placed on them they can build up a lot of heat A ventilation appliance in stalled above the cooker may become dam aged or catch fire Only operate the gas burners with c...

Страница 4: ...ay damage the ap pliance The air extraction duct must be installed with a gradient of at least 1 from the appliance If you put incorrect stress on the design elements they may break off Do not pull design elements Do not place objects on the design elements or hang objects from them There is a risk of surface damage if you do not peel off the protective film Remove the protective film from all par...

Страница 5: ...veyed into a non functioning smoke or ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conveyed through the external wall a tele scopic duct should be used 4 2 Air recirculation mode The air which is drawn in is cleaned by the grease fil ters and an odour filter and conveyed back into the room To bind odours in circulating air mode you must i...

Страница 6: ... odor filter replacement LZ11IXB16 LongLife air recirculation set LZ11ITD11 Long Life odour filter re placement LZ10ITP00 7 Basic operation 7 1 Switching on the appliance Press a The appliance starts at fan setting 1 7 2 Setting a fan level Press or 7 3 Switching off the appliance Press Note If the fan is running at level 2 or 3 press twice 7 4 Switching on intensive mode If particularly strong od...

Страница 7: ...in the interior of the appliance may cause explosions Never use highly caustic alkaline or highly acidic cleaning agents In particular do not use commer cial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods WARNING Risk of electric shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the...

Страница 8: ...maged if they are squeezed Do not squeeze the grease filters Note When cleaning the grease filter in the dish washer light discolouration may occur This discoloura tion has no effect on the performance of the metal grease filters Requirement The grease filters have been removed 1 Observe the information regarding the cleaning agents 2 Place the grease filters loosely into the dishwasher Do not cle...

Страница 9: ...ecessary costs WARNING Risk of injury Improper repairs are dangerous Repairs to the appliance should only be carried out by trained specialist staff If the appliance is defective call Customer Service WARNING Risk of electric shock Incorrect repairs are dangerous Repairs to the appliance should only be carried out by trained specialist staff Only use genuine spare parts when repairing the applianc...

Страница 10: ...rning used elec trical and electronic appliances waste electrical and electronic equip ment WEEE The guideline determines the frame work for the return and recycling of used appliances as applicable throughout the EU 11 Customer Service If you have any queries on use are unable to rectify faults on the appliance yourself or if your appliance needs to be repaired contact Customer Service Detailed i...

Страница 11: ...r in the room if the appliance is being operated in exhaust air mode at the same time as a room air dependent heat producing appli ance is being operated It is only possible to safely operate the ap pliance if the pressure in the room in which the heating appliance is installed does not drop more than 4 Pa 0 04 mbar below at mospheric pressure This can be achieved whenever the air needed for combu...

Страница 12: ...r slowly Take hold of the filter cover after opening until it no longer swings out Close the filter cover slowly WARNING Risk of electric shock Sharp edged components inside the appli ance may damage the connecting cable Do not kink or trap the connecting cable Improper installation is dangerous Connect and operate the appliance only in accordance with the specifications on the rating plate Connec...

Страница 13: ...does not provide any war ranty for faults attributable to the pipeline Use a short straight exhaust air pipe with as large a pipe diameter as possible Long rough exhaust air pipes many pipe bends or small pipe diameters reduce the suction power and increase the fan noise Use an exhaust pipe that is made of non combust ible material To prevent condensate from returning fit the ex haust pipe with a ...

Страница 14: ...er cover and pull it down in a single swift motion 3 Undo the hinge lock and remove the filter cover 4 Remove the grease filters To avoid causing damage do not bend the grease filters 5 Undo the control panel cabling and cabling for the lighting 6 Undo the screws in the frame and remove the frame Preparing circulating air mode 1 Position the filter retainer correctly on the motor and turn it to th...

Страница 15: ...d from the interior 5 Restore the control panel cabling and the cabling for the lighting The plug can only be inserted into one position 6 Ensure that the connector has engaged correctly 7 Fit the grease filters To avoid causing damage do not bend the grease filters 8 Attach and close the filter cover Establishing the exhaust air connection 1 Secure the exhaust pipe to the air pipe connector 2 Est...

Страница 16: ...ctions for the electrical connection Page 12 Removing the appliance WARNING Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Disconnect the appliance from the power supply 2 Loosen the exhaust pipe 3 Open the filter cover if required 4 Remove the grease filters To avoid causing damage do not bend the grease filters 5 Remove the frame 6 Undo the control p...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...hen GERMANY www siemens home bsh group com Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom Manufactured by BSH Hausgeräte GmbH under the trademark licence of Siemens AG ...

Отзывы: