en
Faults and what to do about them
48
Information on the display panel
Faults and what to do about them
Display
Cause/Remedy
E:30
Door is not closed properly. Close the door and restart.
E:10
r
■
Lights up
(no water supply): Water tap turned on? Filter in the water supply is
blocked?
"Filter in the water supply is blocked" on page 45
Is the supply hose kinked or trapped?
E
lights up
The childproof lock is activated – deactivate it.
The symbol
k
flashes
Run the
Drum Clean
programme to clean and care for the drum and the outer tub.
Notes
■
Run the programme without laundry.
■
Use washing powder or a detergent containing bleach. To prevent foaming,
only use half the amount of detergent recommended by the detergent manu-
facturer. Do not use detergent designed for woollens or delicates.
E:21
■
Drain pipe or water drain hose is blocked. Clean the drain pipe and the water
outlet hose.
■
Drain pipe or water drain hose is caught or jammed. Ensure that the drain pipe
and water drain hose are not kinked or trapped.
■
The drain pump is blocked.
"Drain pump is blocked" on page 44
■
The drain hose at the siphon is blocked.
"The drain hose at the siphon is blocked" on page 45
■
The water drain hose is connected too high. Install the water outlet hose at a
maximum height of 1 meter.
E:12
There is water in the base trough, the appliance is leaking. Turn off the tap. Call
customer services.
E:11
Check drain hose installation. Switch off the appliance , check and reset
the routing of drain hose, restart the program.
Faults
Cause/Remedy
Water is leaking from the
appliance.
■
Attach the drain hose correctly or replace it.
■
Tighten the screw fitting on the supply hose.
The door cannot be
opened.
■
- - - (Rinse hold = no final drain) is activated (depending on the module).
Continue the programme by selecting
0
[
Spin/Drain
and pressing
A
Start/Reload.
■
The temperature in drum is too high to open the door.
■
The safety function is activated. Stop the programme?
■
The water level in drum is too high.
■
Can the door only be opened by the emergency release?