Parameter reference
8.8 Communication (4.)
HydroRanger 200 HMI
268
Operating Instructions, 06/2018, A5E36281317-AC
8.8.3
Communications timeout (4.3.)
Sets the maximum time allowed between receiving a request and transmitting the response.
Index
Communications Port
Options
Range: 0 ... 60 000 milliseconds
Preset: 5 000 milliseconds
If the maximum time is exceeded, no response will be transmitted, and the action required
may not be completed.
8.8.4
Protocol (4.4.)
Sets the communications protocol used between the device and other devices.
Index
Communications Port
Options
Communications Port disabled
Dolphin protocol
Modbus ASCII slave serial
*Modbus RTU slave serial
The device supports the internationally recognized Modbus standard in both ASCII and RTU
formats. Other protocols are available with optional SmartLinx cards.
8.8.5
Serial baud rate (4.5.)
Sets the communication rate with the master device.
Index
Communications Port
Options
4.8 kbaud
9.6 kbaud
*19.2 kbaud (preset for Port 2)
*115.2 kbaud (preset for Port 1)
This specifies the rate of communication in kbaud. Any value may be entered but only the
values shown above are supported. The baud rate should reflect the speed of the connected
hardware and protocol used.
Содержание HydroRanger 200 HMI
Страница 2: ......
Страница 20: ...Introduction 1 5 Notes on warranty HydroRanger 200 HMI 18 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 24: ...Safety notes HydroRanger 200 HMI 22 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 28: ...Description 3 5 Modbus communication HydroRanger 200 HMI 26 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 159: ...Parameter reference 8 2 Parameter indexing HydroRanger 200 HMI Operating Instructions 06 2018 A5E36281317 AC 157 ...
Страница 276: ...Parameter reference 8 10 Language 6 HydroRanger 200 HMI 274 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 322: ...Pump control reference B 13 Other pump controls HydroRanger 200 HMI 320 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 352: ...Communications C 41 Single parameter access SPA HydroRanger 200 HMI 350 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 354: ...Updating software HydroRanger 200 HMI 352 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 359: ...HydroRanger 200 HMI Operating Instructions 06 2018 A5E36281317 AC 357 Conduit entry for Class I Div 2 applications F ...
Страница 360: ...Conduit entry for Class I Div 2 applications HydroRanger 200 HMI 358 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 361: ...Conduit entry for Class I Div 2 applications HydroRanger 200 HMI Operating Instructions 06 2018 A5E36281317 AC 359 ...
Страница 362: ......
Страница 372: ...Programming chart G 1 Programming chart HydroRanger 200 HMI 370 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 390: ...LCD menu structure H 1 LCD Menu Structure HydroRanger 200 HMI 388 Operating Instructions 06 2018 A5E36281317 AC ...
Страница 403: ......