Starting Up HiPath 3000
P31003-H3560-S403-54-7620, 09/05
5-6
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
start_h3.fm
Starting Up HiPath 3800
5.2.3
Carrying Out a System Reload
After supplying the system with power, you must carry out a system reload.
Procedure
Press and hold down the reset switch for at least 5 seconds (FAIL LED (red) goes out). If you
do not hold down the reset switch for a full 5 seconds, the system may perform a reset rather
than a reload or may not reload properly.
>
The reset/reload switch is tested by a Field Programmable Gate Array (FPGA). This
FPGA is loaded by the processor when starting up the HiPath 3800 and is only fully
functional after the loading process is complete. If the reset/reload switch is activated
during loading, then it is not possible to evaluate the cause of the restart. For this
reason, the reset/reload switch may only be activated after the system startup (green
Run LED lights up).