Installing HiPath 3000
P31003-H3560-S403-54-7620, 09/05
4-156
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
inst_h3.fm
Installing HiPath 3750, HiPath 3700
Width of the peripheral boards
Peripheral boards are divided into
●
Wide boards requiring a slot 45 mm (1.75”) wide:
–
TML8W with GEE8
Use a 45 mm slot even if you are not installing a GEE8 so that you can easily add a
GEE8 later.
–
TMDID8 (for U.S. only)
●
Narrow boards requiring a slot 30 mm (1.2”) wide (= all other boards)
You can insert wide boards into a 30 mm (1.2") slot. but if you do so, you can no longer use the
slot to its right.
Initializing the Boards
The system software detects the boards in ascending order, starting with the lowest installation
position the first time the system starts up. The system initializes subscriber line circuits and
ports in the sequence indicated by the arrow (Figure 4-89).
The system activates all connected boards in the following situations:
●
The maximum configuration has not yet been reached. While sequentially scanning the
slots for each board, the system software checks whether the maximum number of stations
or trunks has been exceeded. If it has, the board is not activated. The board LED shows
the board’s status.
●
At least one B channel on line trunk modules is available for the slot (only the available
number of B channels is activated).
7
Caution
Always wear an antistatic wristband when working on the system (especially when
handling boards).
Содержание HiPath 3000 V3.0 or later Gigaset M1 Professional
Страница 1: ...HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual ESHB 60 004 05 09 22 09 05 ...
Страница 1168: ...Figures P31003 H3560 S403 54 7620 09 05 W 12 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOF fm ...
Страница 1178: ...Tables P31003 H3560 S403 54 7620 09 05 X 10 HiPath 3000 V6 0 HiPath 5000 V6 0 Provisional Service Manual hp3hp5shLOT fm ...
Страница 1201: ......