boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-277
Boards for HiPath 3000
Peripheral Boards
Notes on DSP diagnosis
You can use the trace function built into the TMAMF module to diagnose malfunctions or obtain
more precise error analysis. The subminiature D connector provides information about MFC-
R2 signaling. To activate the trace function, you must connect a PC with a terminal emulation
program (such as Microsoft HyperTerminal).
Terminal configuration:
●
Bits per second = 19,200
●
Data bits = 8
●
Stop bit = 1
●
Parity = none
●
Flow control = none
Pin assignments of the diagnostic cable
Figure 3-115
Pin Assignments of the TMAMF Diagnostic Cable
PC: RS-232 interface
1
TMAMF: Subminiature D connector
2 3 4 5
6 7 8 9
1
2
3
4
5
6
7
8
9
1
2
3
5
1
3
2
5