boards.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-265
Boards for HiPath 3000
Peripheral Boards
3.3.27
TLA2 (Not for U.S.), TLA4 (Not for U.S.), TLA8 (Not for U.S.)
Introduction
The MSI boards TLA2, TLA4 and TLA8 provide 2, 4 and 8 analog trunks (DP and DTMF dialing
method) for HiPath 3550 and HiPath 3350 (wall housing).
Interfaces
Figure 3-110
TLA2, TLA4 (Not for U.S.) - Interfaces (S30817-Q923-Bxxx, -Axxx)
Table 3-117
TLA2, TLA4 (Not for U.S.) - Contact Assignments
Contact
Connector X2
Connector X4
1
a trunk 1
GND for GEE50 FKR, otherwise free
2
b trunk 1
b trunk 1
3
a trunk 2
a trunk 1
4
b trunk 2
b trunk 2
5
a trunk 3
1
1
Not for TLA2
a trunk 2
6
b trunk 3
1
b trunk 3
1
7
a trunk 4
1
a trunk 3
1
8
b trunk 4
1
b trunk 4
1
9
a trunk 4
1
10
Call charging module assignment (GMZ)
X1
50
2
TLA2/4
X4
X2
1
10
1
8
1
8
To
CUP/
CUC
T/R ports
MSI 1 - 4
To CO
(CO 3, 4
not for
TLA2)
to GEE
Module
X3 (free)