3.2.10
DBSAP
A prerequisite for expanding HiPath 3800 to a two-cabinet system is that the DBSAP (
D
river
B
oard for
S
ynergy
A
ccess
P
latform) board is mounted on the backplane of the expansion cab-
inet.
DBSAP ensures that the expansion cabinet receives HDLC, PCM and clock signals from the
basic cabinet. In addition, an ID signal is created which indicates the availability of an expan-
sion cabinet to the CBSAP.
Figure 3-13
DBSAP (S30807-Q6722-X)
>
The cable (C39195-Z7611-A10) is used as the connection cable between basic cab-
inet (X201 jack) and expansion cabinet (DBSAP board). To ensure smooth opera-
tion, use only shielded cables with a maximum length of 1 m.
Front
With 68-pin DB68 mini-jack for connect-
ing the connection cable to the basic cab-
inet
Back
With four jacks for plugging into the
backplane of the expansion cabinet