Boards for HiPath 3000
Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
3-276
HiPath 3000/5000 V9, Service documentation
boards.fm
Peripheral boards
–
Loop start setting = pins 3–4 closed (default)
–
Ground start setting = pins 1–2 closed
[ground start not possible for TLANI8-IM and TLANI8-BRA]
Contact assignments
Table 3-131
TLANI2, TLANI4 - Contact Assignments
Contact
Connector X2
Connector
X3
Connector X4 (ALUM)
1
a, trunk 1
Not used
b
ALUM1: Subsc. line module con-
nection
2
b, trunk 1
a
3
a, trunk 2
b
ALUM2: Subsc. line module con-
nection
4
b, trunk 2
a
5
a, trunk 3
b
ALUM1: Analog telephone connec-
tion
6
b, trunk 3
a
7
a, trunk 4
b
ALUM2: Analog telephone connec-
tion
8
b, trunk 4
a
Table 3-132
TLANI8:contact assignments
Contact
Connector X2
Connector X4
1
a, trunk 1
a, trunk 5
2
b, trunk 1
b, trunk 5
3
a, trunk 2
a, trunk 6
4
b, trunk 2
b, trunk 6
5
a, trunk 3
a, trunk 7
6
b, trunk 3
b, trunk 7
7
a, trunk 4
a, trunk 8
8
b, trunk 4
b, trunk 8
Содержание HiPath 3000 Series