background image

lan2delot.fm

A31003-K5020-S100-6-7620
Service Manual

0-5

For internal use only

Tables

Tables

0

Table 1-1

Starting Hicom system administration (Service) . . . . . . . . . . . . . . . . . . . .   1-4

Table 2-1

HXGS application option/slot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-1

Table 2-2

HXGS hardware variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-2

Table 2-3

Contact assignment of the HXGS LAN interfaces. . . . . . . . . . . . . . . . . . .   2-4

Table 2-4

HXGS V.24 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-5

Table 2-5

HXGM application option/slot  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-6

Table 2-6

HXGM hardware variants  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-6

Table 2-7

RJ45 socket assignment (HXGM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-8

Table 2-8

Assignment of the SIPAC-RJ45 LAN adapter . . . . . . . . . . . . . . . . . . . . . .   2-9

Table 2-9

Assignment of the CHAMP-RJ45 LAN adapter cable . . . . . . . . . . . . . . .   2-10

Table 2-10

HXGM LED concept  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-10

Table 2-11

Contact assignment of the HXGM LAN interfaces  . . . . . . . . . . . . . . . . .   2-11

Table 2-12

V.24 socket assignment (HXGM2)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-11

Table 2-13

Slots  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-14

Table 2-14

Installation procedure in the case of OfficePoint/Com  . . . . . . . . . . . . . .   2-15

Содержание hicom 150 H optiset E standard

Страница 1: ...Hicom 150 H Service Manual HiPath HG 1500 V 2 0 ...

Страница 2: ...ication Networks Hofmannstraße 51 D 81359 München Reference no A31003 K5020 S100 6 7620 Printed in the Federal Republic of Germany Subject to availability Right of modification reserved 1PA31003 K5020 S100 6 7620 1P A31003 K5020 S100 6 7620 ...

Страница 3: ...1 2 3 4 5 6 7 8 9 10 A31003 K5020 S100 6 7620 Hicom 150 H HiPath HG 1500 V 2 0 Service Manual Installation Introduction Additional information Administration Startup ...

Страница 4: ... 1 2 HXGM 2 6 2 1 2 1 HXGM V 24 interface 2 11 2 1 3 Interfaces to the LAN 2 12 2 2 Part numbers 2 13 2 3 HiPath HG 1500 installation 2 14 2 3 1 Installation requirements 2 14 2 3 2 Slot 2 14 2 3 3 Installation procedure 2 15 3 Startup 1 3 1 Initial startup of HiPath HG 1500 3 1 3 1 1 Initial startup Remote via modem 3 1 3 1 2 Startup via ARP 3 2 3 1 3 Initial startup via the serial interface 3 3 ...

Страница 5: ...Contents For internal use only A31003 K5020 S100 6 7620 0 2 Service Manual lan2detoc fm 5 1 2 Bus topology 10 Base2 5 1 5 2 SW upgrade 5 3 5 3 Firmware Download 5 3 ...

Страница 6: ...1 X X100 2 3 Figure 2 2 HXGS2 interfaces with 2nd LAN S30810 Q2939 X000 X100 2 3 Figure 2 3 HXGM interfaces S30810 Q2930 Q2940 X X100 2 7 Figure 2 4 Adapter for HXGM backplane 2 8 Figure 2 5 LAN adapter cable U S only 2 9 Figure 3 1 Installation for gatekeeper mode 3 4 Figure 5 1 10 100 BaseT cabling 5 1 Figure 5 2 10 Base2 cabling 5 2 ...

Страница 7: ...Figures For internal use only A31003 K5020 S100 6 7620 0 4 Service Manual lan2delof fm ...

Страница 8: ...e 2 4 HXGS V 24 interface 2 5 Table 2 5 HXGM application option slot 2 6 Table 2 6 HXGM hardware variants 2 6 Table 2 7 RJ45 socket assignment HXGM 2 8 Table 2 8 Assignment of the SIPAC RJ45 LAN adapter 2 9 Table 2 9 Assignment of the CHAMP RJ45 LAN adapter cable 2 10 Table 2 10 HXGM LED concept 2 10 Table 2 11 Contact assignment of the HXGM LAN interfaces 2 11 Table 2 12 V 24 socket assignment HX...

Страница 9: ...Tables For internal use only A31003 K5020 S100 6 7620 0 6 Service Manual lan2delot fm ...

Страница 10: ...com Xpress LAN and HiPath HG 1500 create a bridge between the LAN and the ISDN network via an integrated HXGS HXGM board Suitable for Hicom 150 E Office Version 2 2 and later or Hicom 150 H V 1 0 or later Office Point OfficeCom OfficePro model The following implementation scenarios are possible Voice gateway between LAN H 323 and standard telephones e g Netmeet ing Telephoning from the PC voice ov...

Страница 11: ...ne TCP IP address may be necessary if several services are to be configured voice fax file transfer etc 1 2 Short description HiPath HG 1500 is an expansion card for Hicom 150 E Office Hicom 150 H Point Com Pro It is used to connect a local LAN to Hicom systems and to link external LANs via the system s ISDN interface Telematics and CTI functions are also support ed The connection to the local LAN...

Страница 12: ...vided for entering and modifying data e g the IP address of the customer LAN or ISDN numbers assigned to a communication part ner The data is permanently stored in HiPath HG 1500 HiPath HG 1500 Assistant also facilitates the storage of a corresponding configuration file This can then be re trieved if a board needs replacing The tool also provides a facility for querying the software version Access...

Страница 13: ...formation is contained in the Hicom 150 E Office Rel 2 0 3 0 Service Man ual or Hicom 150 H V1 0 Table 1 1 Starting Hicom system administration Service Step Input Explanation 1 95 Start system administration 2 31994 User 31994 default 3 31994 Password 31994 default or 1 Change user and or password 2 Confirm user and or password ...

Страница 14: ...iPath HG 1500Point Com Pro for call numbers used by Hicom 150 E Office Hicom toll restriction for outgoing seizure is performed based on this trunk access in the same way as for outgoing calls 1 5 3 Gatekeeper The following functions are performed by a gatekeeper in an H 323 network Registering H 323 end units Managing rights and services Converting station numbers to logical names or IP addresses...

Страница 15: ...g used IP telephony can also be implemented in H 323 networks without gatekeepers Note however that the con nection can only be set up via the IP address in this case so no authorizations and bandwidth control are possible In general the following applies without gatekeepers many features may be dis abled or subject to severe restrictions ...

Страница 16: ...vironment The board supports up to 16 B channels The following board variants are available HiPath HG 1500 HXGS Voice and Data S30810 Q2931 X HiPath HG 1500 HXGS Data only S30810 Q2931 X100 HiPath HG 1500 HXGS2 Voice and Data 2nd LAN interface S30810 Q2939 X000 HiPath HG 1500 HXGS2 Data only 2nd LAN interface S30810 Q2939 X100 Board slot Table 2 1 HXGS application option slot Possible application ...

Страница 17: ... for connection to a LAN X3 8 pin Western socket for LAN 10 100 Base T RJ45 socket twisted pair for station X4 8 pin Western socket for LAN 10 Base T RJ45 socket twisted pair for trunk connection for HXGS2 board with 2nd LAN interface only 2 boards may be operated in parallel OfficeCom old HW CBFC S30810 Q2950 X OfficeCom new HW CBPC S30810 Q2932 A201 Table 2 2 HXGS hardware variants System type S...

Страница 18: ...he transmission medium for 10 100 Base T and 10 Base T Figure 2 1 HXGS interfaces S30810 Q2931 X X100 Figure 2 2 HXGS2 interfaces with 2nd LAN S30810 Q2939 X000 X100 LAN connec tion to CUC CUP HXGS V 24 X2 10 100 Base T X3 50 X1 2 LAN connec tions to CUC CUP HXGS2 with 2nd LAN interface V 24 X2 10 100 Base T station X3 50 X1 2 10 Base T trunk X4 ...

Страница 19: ... interface The Serial Interface Cable SIC S30122 K5468 X3 can be connected via a 6 pin MiniDin socket on the front panel of the HXGS The SIC performs level conversion from TTL signals HXGS to V 24 9 pin Sub D socket Depending on the SIC the maximum authorized transmission rate for the V 24 interface is 19 2 kBit s Asynchro nous transmission only is supported The interface is used for administratio...

Страница 20: ...1003 K5020 S100 6 7620 Service Manual 2 5 For internal use only Installation Table 2 4 HXGS V 24 interface Pin Signal I O Function 1 GND 2 TXD O Transmit Data 3 CTS I Clear to Send 4 RXD I Receive Data 5 RTS O Request to Send 6 5V 7 GND ...

Страница 21: ...face S30810 Q2940 X000 HiPath HG 1500 HXGM2 Data only 2nd LAN interface S30810 Q2940 X100 Board slot Table 2 5 HXGM application option slot Possible application Boards Slot OfficePro Hicom 150 E as of V 2 2 P30370 P720 A680 Hicom 150 H as of V 1 0 P30370 P800 A680 Hicom 150 H as of V 1 2 P30370 P820 A680 3 All slots except 2 Several boards may be operated in parallel Table 2 6 HXGM hardware varian...

Страница 22: ...he board is connected to the system via the backplane An adapter for the back plane part number C39228 A7195 A10 US backplane C39195 Z7404 A10 is used to connect the LAN with an RJ45 connector see Figure 2 4 Figure 2 3 HXGM interfaces S30810 Q2930 Q2940 X X100 HXGM HXGM2 to BP V 24 X10 Backplane LAN 2 X8 LAN 1 X9 LED H2 green LED H1 red LAN 2 for HXGM board with 2nd LAN interface only Adapter conn...

Страница 23: ... Bob Smith Termination for the two unused wire pairs in a four pair twisted pair cable Figure 2 4 Adapter for HXGM backplane Table 2 7 RJ45 socket assignment HXGM Pin Signal I O Function 1 TDP O Transmit Data 2 TDN O Transmit Data 3 RDP I Receive Data 4 TT1 I Transmit Termination 1 5 TT2 I Transmit Termination 2 6 RDN I Receive Data 7 RT1 I Receive Termination 1 8 RT2 I Receive Termination 2 RJ45 ...

Страница 24: ...r cable The adapter is connected to the CHAMP socket on the rear of the backplane which is assigned to the HG 1500 slot Both the adapter cable and the connector are shielded Figure 2 5 LAN adapter cable U S only Table 2 8 Assignment of the SIPAC RJ45 LAN adapter SIPAC connec tor RJ45 socket Signal B1 1 TDP C2 2 TDN B3 4 TT1 C4 5 TT2 B5 3 RDP C6 6 RDN B7 7 RT1 C8 8 RT2 10 100 Base T 10 Base T femal...

Страница 25: ...6 3 RDP 47 6 RDN 48 7 RT1 49 8 RT2 25 50 Housing Shield Table 2 10 HXGM LED concept H1 red H2 green Meaning Flashing Off Board is included in Firmware no valid SW on board therefore V 24 charge mode On Off Board is included in Firmware e g following reset re boot On Off Off Board at SW start reboot Off Off On Board in idle status following reboot call number of logon router Off On At least one B c...

Страница 26: ... the SIC the maximum authorized transmission rate for the V 24 interface is 19 2 kBit s Asynchro nous transmission only is supported The interface is used for administration purposes It can be used for software updates or board configuration It can also be used for software debugging Table 2 11 Contact assignment of the HXGM LAN interfaces X9 LAN1 10 100 Base T X8 LAN 2 10 Base T Function 1 1 Tran...

Страница 27: ...tional standards for electrical safety and elec tromagnetic compatibility EMC The electrically isolated coupling of the board at the LAN is performed by the send and receive transmitter The maximum transmission speed of this baseband transmission technology is 100 MBit s the Manchester signaling code is used The HiPath HG 1500 boards HXGS and HXGM are provided with a 10 100MB Au tosense LAN port T...

Страница 28: ...P30300 P1530 A1 P30300 P1530 A1 P30300 P1530 A1 vCAPI SW P30300 P1561 A1 P30300 P1561 A1 P30300 P1561 A1 CTI TAPI 1P 4 clients P30152 P1091 A1 P30152 P1091 A1 P30152 P1091 A1 CTI TAPI 3P V2 30 users F50035 E302 X11 F50035 E302 X11 F50035 E302 X11 CTI TAPI 3P V2 80 users F50035 E302 X12 F50035 E302 X12 F50035 E302 X12 CTI TAPI 3P V2 250 users F50035 E302 X13 F50035 E302 X13 F50035 E302 X13 Hicom cl...

Страница 29: ...ry for the HXGS HXGM board with 2nd LAN 2 3 2 Slot Special country variants are not provided for Examples of maximum system config urations Table 2 13 Slots Maximum system configurations for Hicom 150 E OfficePro are contained in the Hi com 150 E Office Hicom 150 H Service Manual System Slot Configuration Trunk Station OfficePoint 2 SLA 4 8 16 SLU8 STLS 2 4 TLA 2 4 8 HiPath HG 1500 16 ports ISDN S...

Страница 30: ...Table 2 14 Installation procedure in the case of OfficePoint Com This sequence must be observed in order to guarantee successful LAN board login Note In the case of Hicom 150 E H OfficePro the board can be plugged and unplugged without disconnecting the power supply Step Task 1 Remove the power plug 2 Insert the board 3 Insert the power plug ...

Страница 31: ...HiPath HG 1500 boards Installation For internal use only A31003 K5020 S100 6 7620 2 16 Service Manual lan2de c02 ...

Страница 32: ...dation Pro 748 Com 686 Point 69 2 Transfer the changes into Hicom using Transfer data 3 The following changes will automatically be made in the customer data base for HiPath HG 1500 the ISDN peer remote default will be set with the following parameters IP address 10 186 237 64 CHAP user ID 31994 Host On CHAP password 31994 V 34 peer Yes the ISDN2 interface is assigned the IP address 10 186 237 63 ...

Страница 33: ...he board on entry to the customer database The HiPath HG 1500 default IP address 10 144 233 63 is reserved for startup and cannot be used as a permanent IP address in the network Security note As long as a customer database has not been transferred to the board the process described above can be used by every PC in the LAN 5 HiPath HG 1500 can now be administered remotely with Assistant Xpress LAN...

Страница 34: ...al up network must be installed separately from the op erating system Note The SLIP configuration on the PC is described in detail in the Administration Docu ments Hicom 150 E Office for HiPath HG 1500 Step Task 1 Connect the serial interface cable S30122 X5468 X3 2 Install Assistant Xpress LAN HG 1500 3 Configure the IP address 1 0 0 2 of the PC SLIP 4 From the DOS command window ping HiPath HG 1...

Страница 35: ...tations registered at the gatekeeper H 323 standard clients such as Net meeting 3 01 HiNet LP5100 HiNet TA1100 etc Note In order to reach a port station line of group 1 all stations of group 2 must dial an additional code This code is deleted in the direction to the Hicom by HiPath HG 1500 and inserted for traffic in the reverse direction i e stations of group 1 do not dial the code The code must ...

Страница 36: ...onfigure the clients with a gatekeeper connection using IP address 255 255 255 255 Clients without a gatekeeper connection must be configured with the fixed IP addresses of the corresponding PCs 3 Under Voice Clients Xpress Clients There are no additional aspects to be noted here Step Task 1 Capacity Characteristics Set the IRQ interval to 0 if the registered endpoints do not need to be cy clicall...

Страница 37: ...de which must match the HiPath HG 1500 gateway prefix set up in the HLB0 e g 0 only digits possibly mul tiple 4 Enable Allow as default for online endpoints if the service is to be as signed to all endpoints registered at the gateway otherwise the service will need to be individually assigned to each endpoint that may use it 5 Enable Allow for public endpoints from other zones if endpoints from ot...

Страница 38: ...ace and error memory If system crashes have occurred in connection with the board make sure that you also produce a stack dump and submit it together with the traces to the responsible Development department The traces and the stack dump can withstand a reset but are lost in the event of a power failure 4 2 Determining the firmware version of the board The firmware version of the board can be dete...

Страница 39: ...Tracing with development trace Administration For internal use only A31003 K5020 S100 6 7620 4 2 Service Manual lan2de c04 ...

Страница 40: ...hernet A standard hub emulates a bus internally If a cable malfunctions only one terminal is affected The integrated HiPath HG 1500 can be connected di rectly Figure 5 1 10 100 BaseT cabling Notes 10 100 MBit s Autosense Max total length from HUB switch to PC 100 m incl PATCH cable 5 1 2 Bus topology 10 Base2 The traditional but now redundant cabling method for Ethernet LANs Coaxial cable is used ...

Страница 41: ...bling is becoming increas ingly popular The integrated HiPath HG 1500 can only be connected via a hub or switch Figure 5 2 10 Base2 cabling Note The coaxial cable must have terminating resistors at both ends No spur lines are permitted in the coaxial cable The T units must be positioned directly on the terminals Max length of the LAN is 185 m Hicom 150 E Office Hicom 150 H PC PC PC LAN PC HUB ...

Страница 42: ...he Assistant This fea ture is used to upgrade the firmware of a board to a new version Such a firmware upgrade should only be performed if there are valid reasons since the operation is comparable to a BIOS update on the PC Select the APS file with the firmware to be transferred File Open dialog Assistant I checks as to whether the software of the selected HiPath HG 1500 system supports a firmware...

Страница 43: ... are contained in the APS file This is followed by a warning message If the user decides to continue with the transfer the firmware will be transferred Once the transfer has been completed successfully the user is prompted to con firm the changeover to the new firmware Another warning message appears Assistant I prompts HiPath HG 1500 to perform changeover and HiPath HG 1500 reports whether the ch...

Страница 44: ...ter Telephony Integration DFÜ German abbreviation for Dial Up Networking DSP Digital Signal Processor DSS1 Digital Subscriber Signaling System One D channel protocol EMC Electromagnetic Compatibility FW Firmware GSM Global System for Mobile Communication GK Gatekeeper H 323 ITU standard for voice over LAN HFA Hicom Feature Access MDF Main Distribution Frame HXGM Hicom Xpress Gateway Medium HXGO Hi...

Страница 45: ...ARP Reverse Address Resolution Protocol RAS Remote Access Service SIC Serial Interface Cable SLA Subscriber Line Analog Hicom board SLIP Serial Line Interface Protocol SLU Subscriber Line UP0 E Hicom board SMR Service Maintenance Release SNMP Simple Network Management Protocol STLS Subscriber Trunk Line S0 Hicom board CTRL Control TAPI Telephony Application Programming Interface TCP Transmission C...

Страница 46: ...atekeeper 1 5 gatekeeper mode installing 3 4 H Hicom password concept 1 4 HiPath HG 1500 Functional environment 1 5 Parallel operation 1 5 HiPath HG 1500 Assistant 1 3 HiPath HG 1500 boards 2 1 HiPath HG 1500 installation 2 14 HXGM 2 6 HXGM application option slot 2 6 HXGM hardware variants 2 6 HXGM interfaces S30810 Q2930 X X100 2 7 HXGM LED concept 2 10 HXGM V 24 interface 2 11 HXGS 2 1 HXGS app...

Страница 47: ...ast Cost Routing LCR 1 5 P Part numbers 2 13 R RJ45 socket assignment HXGM 2 8 S Service information 1 3 Short description 1 2 Slot 2 14 Star topology with hub 10 100 BaseT 5 1 Starting Hicom system administration Service 1 4 Startup 3 1 Startup via ARP 3 2 SW upgrade 5 3 T Toll restriction 1 5 Tracing with development trace 4 1 Trunk access 1 5 V V 24 socket assignment HXGM2 2 11 ...