Table 26:
Constraining PNPLL Interface
3.3.3.4.1
Timing for time synchronization
Signal
(Input)
Ports
Alterna-
te
Func-
tion
Input_delay
Load (pF)
Min / Max
Refer-
ence
Functional
characteris-
tics
-min
-max
PNPLL_EXTIN_Ti
me
GPIO_12
A
1.5 ns
4.4 ns
-
CLK_SY
S
asynchronous
Signal
(Output)
Clock-to-Output_delay
-min
-max
PNPLL_Time_Out
GPIO_11
A
4.9 ns
12.4 ns
10 / 30
CLK_SY
S
asynchronous
GPIO_28
C
4.8 ns
12.3 ns
10 / 30
CLK_SY
S
asynchronous