3.2.1 Strapping Pins
During XRESET is active, the Input-Value of following Pins are LATCHED in:
Package Ball Name
Strapping Information
Remark
A_17
Config(0)
see chapter
2.3.10.9.3
A_18
Config(1)
A_19
Config(2)
A_20
Config(3)
A_21
Config(4)
A_22
Config(5)
A_23
Config(6)
DTXR
Boot(0)
see chapter
2.3.10.9.2
XOE_DRIVER
Boot(1)
A_15
Boot(2)
A_16
Boot(3)
XAV_BF
Boot(4)
XRDY_BF
EXT_DRIVER_DISABLE_CS0
see chapter
Remark
:
After XRESET is released, the values are stored. The values must stay stable 120ns after
XRESET is released.