Copyright © Siemens AG 2016. All rights reserved
190
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
XHIF_1_P3_OF
r
(w)
F4h
74h
XHIF_1_P3_CFG r
w
F8h
78h
XHIF_1_VERSION r
FCh
7Ch
1)
The addresses also apply to access from an external host with a 32-bit data bus at the XHIF interface with
XHIF_XCS_R
(XHIF chip select register: offset address = 0x0000). An external host with a 16-bit data bus addresses
on a 16-bit basis (address: 0h, 2h, 4h, 6h, …).
2.3.6.4 Register Description
Module: /HOSTIF
Register:
HOST_CONTROL
Address:
0h
Bits:
0dt0
Reset value:
0h
Attributes: r w
Description:
Selection of the serial or parallel path
Bit
Identifier
Reset
Attr.
Function / Description
0
CONNECT_MODE
0h
r w 0 =parallel connection (XHIF) 1
=serial connection (SPI)
Register:
IP_VERSION
Address:
40h
Bits:
31dt0
Reset value:
100h
Attributes: r
Description:
Metal-fix register for IP Version
Bit
Identifier
Reset
Attr.
Function / Description
7dt0 DEBUG_VERSION
00h
r
IP Debug Version
15dt8 VERSION
01h
r
IP Version
31dt16 IP_CONFIGURATION
0000h
r
IP Configuration
Register:
IP_DEVELOPMENT
Address:
44h
Bits:
31dt0
Reset value:
0h
Attributes: r
Description:
Metal-fix register for IP Development
Bit
Identifier
Reset
Attr.
Function / Description
31dt0 LABEL_STRUCTURE
00000000h r
Design Label
Register:
ACCESS_ERROR
Address:
48h
Bits:
31dt0
Reset value:
20000000h Attributes: r (w)
Description:
Access error register
Bit
Identifier
Reset
Attr.
Function / Description
7dt0 APB_ADDRESS
00h
r
Erroneous APB address in the
HostIF