Parameters
Connector/Binector (BICO)-Parameters
1-430
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
1.4.5
Connector/Binector Output Parameters
Product: SINAMICS G120, Version: 4301300, Language: eng, Type: CO/BO
r0046.0...31
CO/BO: Missing enable sig / Missing enable sig
r0050.0...1
CO/BO: Command Data Set CDS effective / CDS effective
r0051.0...1
CO/BO: Drive Data Set DDS effective / DDS effective
r0052.0...15
CO/BO: Status word 1 / ZSW 1
r0053.1...11
CO/BO: Status word 2 / ZSW 2
r0053.0...11
CO/BO: Status word 2 / ZSW 2
r0054.0...15
CO/BO: Control word 1 / STW 1
r0055.0...15
CO/BO: Supplementary control word / Suppl STW
r0056.0...15
CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
r0056.0...13
CO/BO: Status word, closed-loop control / ZSW cl-loop ctrl
r0722.0...12
CO/BO: CU digital inputs, status / CU DI status
r0723.0...12
CO/BO: CU digital inputs, status inverted / CU DI status inv
r0835.2...8
CO/BO: Data set changeover status word / DDS_ZSW
r0836.0...1
CO/BO: Command Data Set CDS selected / CDS selected
r0837.0...1
CO/BO: Drive Data Set DDS selected / DDS selected
r0898.0...10
CO/BO: Control word sequence control / STW seq_ctrl
r0899.0...11
CO/BO: Status word sequence control / ZSW seq_ctrl
r1198.0...15
CO/BO: Control word setpoint channel / STW setpoint chan
r1199.0...6
CO/BO: Ramp-function generator status word / RFG ZSW
r1204.0...13
CO/BO: Flying restart, V/f control status / FlyRest Vf st
r1205.0...15
CO/BO: Flying restart, vector control status / FlyRest vector st
r1214.0...15
CO/BO: Automatic restart, status / AR status
r1239.8...11
CO/BO: DC brake status word / DC brake ZSW
r1261.0...7
CO/BO: Bypass control/status word / Bypass STW / ZSW
r1406.4...15
CO/BO: Control word speed controller / STW n_ctrl
r1407.0...15
CO/BO: Status word speed controller / ZSW n_ctrl
r1408.0...12
CO/BO: Status word current controller / ZSW I_ctrl
r2129.0...15
CO/BO: Trigger word for faults and alarms / Trigger word
r2135.12...15
CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
r2138.7...15
CO/BO: Control word faults/alarms / STW fault/alarm
r2139.0...12
CO/BO: Status word faults/alarms 1 / ZSW fault/alarm 1
r2197.0...12
CO/BO: Status word monitoring 1 / ZSW monitor 1
r2198.0...13
CO/BO: Status word monitoring 2 / ZSW monitor 2
r2199.0...11
CO/BO: Status word monitoring 3 / ZSW monitor 3
r2225.0
CO/BO: Technology controller fixed value selection status word / Tec_ctrl FW status
r2349.0...12
CO/BO: Technology controller status word / Tec_ctrl stat word
r2379.0...7
CO/BO: Staging status word / Staging ZSW
r2399.0...8
CO/BO: Hibernation status word / Hib ZSW
r3113.0...15
CO/BO: NAMUR message bit bar / NAMUR bit bar
r3859.0
CO/BO: Status word compound brake / ZSW compound brake
r3889.0...6
CO/BO: ESM status word / ESM status word
r11049.0...11
CO/BO: Free tec_ctrl 0 status word / Ftec0 stat_word
r11149.0...11
CO/BO: Free tec_ctrl 1 status word / Ftec1 stat_word
r11249.0...11
CO/BO: Free tec_ctrl 2 status word / Ftec2 stat_word