Command and Drive Data Sets – Overview
Parameters
1-409
© Siemens AG 2009 All Rights Reserved
SINAMICS G120 Control Units CU230P-2 Parameter Manual (LH9), 11/2009
1.3
Command and Drive Data Sets – Overview
1.3.1
Command Data Sets (CDS)
Product: SINAMICS G120, Version: 4301300, Language: eng, Type: CDS
p0641[0...n]
CI: Current limit, variable / Curr lim var
p0700[0...n]
Command source selection / Cmd src sel
p0701[0...n]
Pre-assignment digital input 0 / Pre-assignment DI0
p0702[0...n]
Pre-assignment digital input 1 / Pre-assignment DI1
p0703[0...n]
Pre-assignment digital input 2 / Pre-assignment DI2
p0704[0...n]
Pre-assignment digital input 3 / Pre-assignment DI3
p0705[0...n]
Pre-assignment digital input 4 / Pre-assignment DI4
p0706[0...n]
Pre-assignment digital input 5 / Pre-assignment DI5
p0712[0...n]
Pre-assignment digital input 11 / Pre-assign. DI11
p0713[0...n]
Pre-assignment digital input 12 / Pre-assign. DI12
p0820[0...n]
BI: Drive Data Set selection DDS bit 0 / DDS select., bit 0
p0821[0...n]
BI: Drive Data Set selection DDS bit 1 / DDS select., bit 1
p0840[0...n]
BI: ON/OFF1 / ON/OFF1
p0844[0...n]
BI: 1. OFF2 / 1. OFF2
p0845[0...n]
BI: 2. OFF2 / 2. OFF2
p0848[0...n]
BI: 1. OFF3 / 1. OFF3
p0849[0...n]
BI: 2. OFF3 / 2. OFF3
p0852[0...n]
BI: Operation enable / Operation enable
p0854[0...n]
BI: Master ctrl by PLC / Master ctrl by PLC
p1000[0...n]
Speed setpoint selection / n_set sel
p1020[0...n]
BI: Fixed speed setpoint selection Bit 0 / n_set_fixed Bit 0
p1021[0...n]
BI: Fixed speed setpoint selection Bit 1 / n_set_fixed Bit 1
p1022[0...n]
BI: Fixed speed setpoint selection Bit 2 / n_set_fixed Bit 2
p1023[0...n]
BI: Fixed speed setpoint selection Bit 3 / n_set_fixed Bit 3
p1035[0...n]
BI: Motorized potentiometer setpoint raise / Mop raise
p1036[0...n]
BI: Motorized potentiometer lower setpoint / Mop lower
p1039[0...n]
BI: Motorized potentiometer inversion / Mop inversion
p1041[0...n]
BI: Motorized potentiometer manual/automatic / Mop manual/auto
p1042[0...n]
CI: Motorized potentiometer automatic setpoint / Mop auto setpoint
p1043[0...n]
BI: Motorized potentiometer accept setpoint / Mop accept set val
p1044[0...n]
CI: Motorized potentiometer setting value / Mop set val
p1051[0...n]
CI: Speed limit RFG positive direction of rotation / n_limit RFG pos
p1052[0...n]
CI: Speed limit RFG negative direction of rotation / n_limit RFG neg
p1055[0...n]
BI: Jog bit 0 / Jog bit 0
p1056[0...n]
BI: Jog bit 1 / Jog bit 1
p1070[0...n]
CI: Main setpoint / Main setpoint
p1071[0...n]
CI: Main setpoint scaling / Main setp scal
p1075[0...n]
CI: Supplementary setpoint / Suppl setpoint
p1076[0...n]
CI: Supplementary setpoint scaling / Suppl setp scal
p1085[0...n]
CI: Speed limit in positive direction of rotation / n_limit pos
p1088[0...n]
CI: Speed limit in negative direction of rotation / n_limit neg
p1108[0...n]
BI: Total setpoint selection / Total setp sel
p1109[0...n]
CI: Total setpoint / Total setp
p1110[0...n]
BI: Inhibit negative direction / Inhib neg dir
p1111[0...n]
BI: Inhibit positive direction / Inhib pos dir
p1113[0...n]
BI: Setpoint inversion / Setp inv
p1122[0...n]
BI: Bypass ramp-function generator / Bypass RFG