Work Safety Information
7
Siemens Building Technologies
Fire Safety & Security Products
01.2006
–
The product does not operate normally when the operating instructions are
followed.
–
The product has been dropped or the cabinet has been damaged.
–
The product exhibits a distinct change in performance, indicating a need for
service.
–
The power cord or plug is frayed or damaged.
2.2 Safety
Guidelines
WARNING
This device must be operated with the original power supply, part number: HJC,
HASU12FB60.
CAUTION
The socket outlet should be installed near the equipment and should be easily
accessible.
CAUTION
Use a power cable that is properly grounded. Always use the appropriate AC
cord that is certified for the individual country. Some examples are listed below:
USA………..UL Switzerland…….SEV
Canada……CSA Britain…………..BASE/BS
Germany…..DE Japan…………...Electric Appliance Control Act.
2.3
Important notice concerning power cord selection
The power cord set for this unit has been enclosed and has been selected
according to the country of destination. It must be used to prevent electric shock.
Use the following guidelines if it is necessary to replace the original cord set, or if
the cord set is not enclosed.
The female receptacle of the cord set must meet IEC-60320 requirements and may
look like this (Figure A1 below):
Figure
A1
Figure
A2
2.3.1
For the United States and Canada
In the United States and Canada the male plug is a NEMA5-15 style (Figure A2),
UL Listed, and CSA Labeled. For units which are mounted on a desk or table, SVT
or SJT type cord sets may be used. For units which sit on the floor, only SJT type
cord sets may be used. The cord set must be selected according to the current
rating for your unit. Please consult the table below for the selection criteria for
power cords used in the United States and Canada.
Code Type
Size of Conductors in Cord
Maximum Current Rating of Unit
SJT 18
AWG
16 AWG
14 AWG
10 Amps
12 Amps
12 Amps
SVT 18
AWG
17 AWG
10 Amps
12 Amps