7 Installation and Commissioning
7.3 Downloading the program
HCS4x00Library
Entry ID: 109478117, V2.2.1, 09/2018
65
S
ie
m
e
n
s
A
G
2018
A
ll r
ig
h
ts
r
e
s
e
rv
e
d
7.2.1
Setting the PG/PC interface
Table 7-3
No.
Action
Remark
1. Open the PG/PC interface settings via
“Start > Control Panel” to set the correct
access path for STEP 7 V14 SP1.
Select “S7ONLINE (STEP 7)” as the
application's access point.
Select your network card with
“(Parameter assignment of your NDIS
CP with TCP/IP protocol (RFC-
1006))”
as the interface configuration used.
Confirm the se
ttings with “OK”.
7.3
Downloading the program
This chapter describes the steps required for the installation of the STEP 7 project.
Table 7-4
No.
Action
Remark
1.
The Step 7 V14 SP1 project can be found on
the HTML page from which you have
downloaded this document (
Save the project
"109478117_HCS4x00_PRJ_v22.zip"
to your hard disk.
2.
Unzip the project and open it in STEP 7 V14
SP1 by double-clicking the file
"109478117_HCS4x00_PRJ_v22.ap14".
3.
Select the corresponding controller folder and
transfer the program to the respective
controller by clicking the “Download to device”
icon.
Note
For more information on downloading the project data, please refer to the S7-
1500 manual (see