8 Operating the Application
8.1 Operating the HCS4x00
HCS4x00Library
Entry ID: 109478117, V2.2.1, 09/2018
74
S
ie
m
e
n
s
A
G
2018
A
ll r
ig
h
ts
r
e
s
e
rv
e
d
No.
Action
Remark
9.
Write “
150
” or “
151
” to tag
“
LHcs4x00_Tags".control.dsNum
for
adopting the field value setpoints, and
set bit
“
LHcs4x00_Tags".control.writeData
.
10. Then reset bit
“
LHcs4x00_Tags".control.writeData
.
Note
11. Open the
“
LHcs4x00_WatchTableGet”
watch
table.
The actual values of the assigned
power output channels show the
respective field value setpoints.
12.
In the “
LHcs4x00_WatchTablePut”
watch table you can use the
“
con
trol.prodStandby”
bit to choose
between operating modes
“Production” and “Standby” and
switch the compensation voltage on
and off via “
control.voltageComp
”.
13. Then reset bit
“
LHcs4x00_Tags".control.heatingOn
again for switching the heating off.