5 How to Work with the Library
5.3 Updating the library
HCS4x00Library
Entry ID: 109478117, V2.2.1, 09/2018
50
S
ie
m
e
n
s
A
G
2018
A
ll r
ig
h
ts
r
e
s
e
rv
e
d
No.
Action
Note
4. Overwrite the master copies in your project
by moving the “Control&Diag” folder from the
master copies of the V2.1 library to the
following project folders via drag-and-drop:
Program blocks
PLC data types
Watch and force tables
When the window “Conflicts detected during
pastings” appears, select the “Replace
existing objects and move to this location”
option.
5.
Select the “Types” folder in the “LHcs_4x00”
V2.2 block library and right-click to select
“Update > Project”.
6. Select the devices you would like to update.
Select the “Delete unused type versions from
the library” update option.
Click “OK” to confirm the update of the
project.