On-Chip Peripheral Components
C541U
6.4.1 Transfer Modes
USB data transfers take place between host software and a particular endpoint on a USB device. A
given USB device may support multiple data transfer endpoints. The USB host treats
communications with any endpoint of a USB device independently from any other endpoint. Such
associations between the host software and a USB device endpoint are called pipes. As an
example, a given USB device could have an endpoint supporting a pipe for transporting data to
the
USB device and another endpoint supporting a pipe for transporting data from
the USB device.
The USB architecture comprehends four basic types of data transfers.
Table 6-4
USB Transfer Modes
Mode
Function
Control
Control data are used to configure devices, data transmission is lossless. Control
pipes are bidirectional, data transfer is possible in both directions via one pipe.
Endpoint 0 is always configured as control endpoint with a maximum buffer
length of 8 bytes. The control endpoint can be configured to handle data packets
of 64 bytes maximum length.
Isochronous
(full speed
mode only)
Isochronous data are continuous and real-time in creation and consumption,
such as voice data. In this case, real-time is defined from frame to frame.
Isochronous data transfer has the highest priority, but is not always lossless.
Isochronous pipes are always unidirectional, so one endpoint can be associated
to an IN pipe or an OUT pipe. The C541U supports up to 64 bytes.
Interrupt
Interrupt data are a small amount of data, which are transferred to the host every
n frames, with n being programmable by the host. Data delivery is lossless.
Interrupt pipes are always unidirectional IN pipes, the maximum data packet
length is limited to 64 bytes.
Bulk
(full speed
mode only)
Bulk data can be a larger amount of data, which can be split by the host in several
data packets witin one frame. Data delivery is lossless.
Bulk pipes are always unidirectional, so one endpoint can be associated to an IN
pipe or an OUT pipe. The maximum data packet length is limited to 64 bytes.
Содержание C541U
Страница 1: ... 8 LW 026 0LFURFRQWUROOHU 8VHU V 0DQXDO http www siem ens d Sem iconductor ...
Страница 7: ......
Страница 21: ...Semiconductor Group 2 6 1997 10 01 Fundamental Structure C541U ...
Страница 37: ...Semiconductor Group 4 6 1997 10 01 External Bus Interface C541U ...
Страница 133: ...Semiconductor Group 6 88 1999 04 01 On Chip Peripheral Components C541U ...
Страница 163: ...Semiconductor Group 8 8 1997 10 01 Fail Safe Mechanisms C541U ...
Страница 185: ...Semiconductor Group 10 14 1997 10 01 OTP Memory Operation C541U ...
Страница 192: ...Semiconductor Group 12 7 Index C541U ...