INTRODUCTION

The Model BTC-1 Backup Tone Card from
Siemens Industry,  Inc. provides two tones
for the MXLV System that can be selected
by dipswitches. This card can be installed on
top of the ACM-1 to provide backup of the
two primary tones should the tone generator
of the ACM-1 fail. The BTC-1 can also be
installed on the OCC-1 Output Control Card
module to provide a default tone when the
low power riser fails and when the OCC-1
loses contact with the MMB.

Select the two backup tones on switch S1 by
matching SW1-SW4 and SW5-SW8 to the
CSG-M (AccuLINK) configuration tone selec-
tions. Table 1 on the next page shows the
switch settings for each available tone.

For additional information on the Voice
System, refer to the MXLV Manual, P/N
315-092036.

INSTALLATION

Remove all system power before installa-
tion, first battery and then AC.

 (To power

up, first connect the AC and then the battery.)

1. Remove the card from its protective bag.

Installation Instructions

Model BTC-1
Backup  Tone Card

2. Refer to the function section of the CSG-M

configuration printout for the tones to be
configured.

3. Set the desired tones on switch S1 using

dipswitches SW1-SW4 for the first tone
selection and dipswitches SW5-SW8 for
the second tone selection.

a. Refer to Figure 2 or 3 on page 3

for the location of S1.

b. Refer to Table 1 for the switch set-

tings and their associated tones.

c. Set the tones (See 

Note 

at the top

of the next page).

Do not install the BTC-1 on the ACM-1
or OCC-1 until the system is ready for
the installation of PC cards. Until then,
keep the BTC-1 in its protective bag.

Mounting

The BTC-1 mounts on either the ACM-1
(See Figure 2) or the OCC-1 (See Figure 3)
with two snap-in type standoffs and a comb-
like connector.

1. Install the standoffs and comb connector

in the component side of the ACM-1 or
the OCC-1, whichever is appropriate.
(See 

Note

 at top of the next page.)

P/N 315-090919-8

Siemens Industry, Inc.
Building Technologies Division
Florham Park, NJ

Siemens Building Technologies, Ltd.
Fire Safety & Security Products
2 Kenview Boulevard
Brampton, Ontario
L6T 5E4 Canada

Содержание BTC-1

Страница 1: ...nstallation Instructions Model BTC 1 Backup Tone Card 2 Refer to the function section of the CSG M configuration printout for the tones to be configured 3 Set the desired tones on switch S1 using dipswitches SW1 SW4 for the first tone selection and dipswitches SW5 SW8 for the second tone selection a Refer to Figure 2 or 3 on page 3 for the location of S1 b Refer to Table 1 for the switch set tings...

Страница 2: ... X X 0 X X X l a g e l l I X X X X X X X X e n o t z H 0 0 9 Note To open a dipswitch press down on the side of the dipswitch marked OPEN To close a dipswitch press down on the side of the dipswitch opposite the side marked OPEN To open a slide switch push the slide to the side opposite the side marked ON To close a slide switch push the slide to the side marked ON X Switch closed OR ON 0 Switch o...

Страница 3: ... into place This takes some effort Be careful be cause once the standoffs are installed they are difficult to remove If it is Figure 3 Mounting the BTC 1 on the OCC 1 Figure 2 Mounting the BTC 1 on the ACM 1 necessary to remove the BTC 1 from either the ACM 1 or the OCC 1 first disconnect the system ELECTRICAL RATINGS t n e r r u C e l u d o M C D V 5 e v i t c A A m 0 1 t n e r r u C e l u d o M ...

Страница 4: ...P N 315 090919 8 Siemens Industry Inc Building Technologies Division Florham Park NJ Siemens Building Technologies Ltd Fire Safety Security Products 2 Kenview Boulevard Brampton Ontario L6T 5E4 Canada ...

Отзывы: