2.3.4 Bus
Connector
Bus Current Consumption
Using the resistor R
RISOLL
, the mean current taken from the bus is set from 2
mA
to
50
mA
. In the range from 2 mA to 10 mA, the SIM 1-2 automatically operates in
the asymmetric modulation mode. This means that to transmit, the mean current
consumption is raised to 10
mA
and then lowered again to the set value.
The set mean bus current must always be at least 1 mA higher than the current
transferred to the application over VREG and VE (including DC/DC).
R
RISOLL
[M
Ω
] = 0.05 * I
BUS
[mA]
Conditions for R
RISOLL
: 100
K
Ω
≤
R
RISOLL
≤
2.5 M
Ω
the capacitor C
VE
must be dimensioned in the permitted range according to the
pulse load by the application or the DC/DC converter.
Caution 1
To achieve the minimum bus current tolerance of 3 %, resistors with a tolerance of
≤
0.1 % must be used. As an alternative, the bus current can be matched over
R
RISOLL
(see also tolerance calculation in section 2.3.7, "Reference Circuit RIREF,
Caution 2
Transistor T1 and its cooling surface must be designed according to the set bus
current consumption and the resulting dissipation loss.
Содержание ASIC SIM 1-2
Страница 6: ...Preface SIM 1 2 6 C79000 G8976 C215 01 ...
Страница 41: ...Technical Specifications SIM 1 2 C79000 G8976 C215 01 41 3 3 Housing MLPQ 40 Drawing of the Housing ...
Страница 44: ...Technical Specifications SIM 1 2 44 C79000 G8976 C215 01 ...
Страница 46: ...Application Examples SIM 1 2 46 C79000 G8976 C215 01 ...
Страница 50: ...Application Examples SIM 1 2 50 C79000 G8976 C215 01 Signal Evaluation in the Demodulator ...
Страница 58: ...Application Examples SIM 1 2 58 C79000 G8976 C215 01 ...