Input Point Module (AFI5100)
The following diagram displays the location of the ports on the AFI5100 :
FOR OUT
Nc C No
OUT 1
Nc C No
OUT 2
Nc C No
OUT 3
Nc C No
OUT 4
Nc C No
DC POWER IN
0V V+ E
LOCAL IN OUT
IN+ IN- OUT+ OUT-
0V V+
12V OUT 2
0V V+
12V OUT 1
B
R
D
-
0
0
00
5
S
ie
m
e
n
s
B
u
ild
in
g
T
e
ch
n
o
lo
g
ie
s
RS-485
E - +
RLY4
RLY3
RLY2
RLY1
RLY5
P
O
W
E
R
A
C
T
IV
IT
Y
T
X
C
O
M
M
S
LK14
LK13
LK12
LK11
LK1
LK 9
LK3
R
X
C
O
M
M
S
IN
PU
T 1
IN
+
IN
-
IN
+
IN
-
IN
PU
T 5
IN
PU
T2
IN
+
IN
-
IN
+
IN
-
IN
PU
T 6
IN
PU
T 3
IN
+
IN
-
IN
+
IN
-
IN
PU
T 7
IN
PU
T 4
IN
+
IN
-
IN
+
IN
-
IN
PU
T 8
IN
PU
T 9
IN
+
IN
-
IN
+
IN
-
IN
PU
T 1
3
IN
PU
T 1
0
IN
+
IN
-
IN
+
IN
-
IN
PU
T 1
4
IN
PU
T 1
1
IN
+
IN
-
IN
+
IN
-
IN
PU
T 1
5
IN
PU
T 1
2
IN
+
IN
-
IN
+
IN
-
IN
PU
T 1
6
IN
PU
T 1
7
IN
+
IN
-
IN
+
IN
-
IN
PU
T 2
1
IN
PU
T 1
8
IN
+
IN
-
IN
+
IN
-
IN
PU
T 2
2
IN
PU
T 1
9
IN
+
IN
-
IN
+
IN
-
IN
PU
T 2
3
IN
PU
T 2
0
IN
+
IN
-
IN
+
IN
-
IN
PU
T 2
4
IN
PU
T 2
5
IN
+
IN
-
IN
+
IN
-
IN
PU
T 2
9
IN
PU
T 2
6
IN
+
IN
-
IN
+
IN
-
IN
PU
T 3
0
IN
PU
T 2
7
IN
+
IN
-
IN
+
IN
-
IN
PU
T 3
1
IN
PU
T 2
8
IN
+
IN
-
IN
+
IN
-
IN
PU
T 3
2
IN
P
U
T
1
IN
P
U
T
2
IN
P
U
T
3
IN
P
U
T
4
IN
P
U
T
5
IN
P
U
T
6
IN
P
U
T
7
IN
P
U
T
8
IN
P
U
T
1
7
IN
P
U
T
1
8
IN
P
U
T
1
9
IN
P
U
T
2
0
IN
P
U
T
2
1
IN
P
U
T
2
2
IN
P
U
T
2
3
IN
P
U
T
2
4
IN
P
U
T
9
IN
P
U
T
1
0
IN
P
U
T
1
1
IN
P
U
T
1
2
IN
P
U
T
1
3
IN
P
U
T
1
4
IN
P
U
T
1
5
IN
P
U
T
1
6
IN
P
U
T
2
5
IN
P
U
T
2
6
IN
P
U
T
2
7
IN
P
U
T
2
8
IN
P
U
T
2
9
IN
P
U
T
3
0
IN
P
U
T
3
1
IN
P
U
T
3
2
FO
R I
N
IN
+ IN
-
F
O
R
N
O
R
M
A
L
LK5
LK7
LK8
FOR EN
FOR DIS
LK 10
S
/N
:
LK2
LK4LK6
F
O
R
E
N
A
B
L
E
F
O
R
O
U
T
P
U
T
1
O
U
T
P
U
T
2
O
U
T
P
U
T
3
O
U
T
P
U
T
4
D
C
O
U
T
2
D
C
O
U
T
1
9
4
5
6
7
8
1
2
3
The following table provides a brief description of each port:
Port Name
Brief Description
1
INPUT 17 – INPUT 32
Input Ports 1 - 32
Inputs for connection to monitoring and input
devices
2
INPUT 1 – INPUT 16
Input Ports 1 - 16
Inputs for connection to monitoring and input
devices
3
FOR IN
Fire Over-ride Input Port
Input for Fire Over-ride wiring
4
DC Power IN
DC power input
5
FOR OUT
Fire Over-ride Output Port
Fire Over-ride for connecting devices in Fire Over-
ride sequence
6
OUT 1 – OUT 4
Output Ports 1 - 4
Auxiliary Relay-driven Outputs
7
12V OUT 1-12V OUT 2
Auxiliary 12 V DC Power Supply 1-2
12 V DC power source
8
LOCAL IN OUT
Tamper In/Out Port
Local input and output for tamper detection and
alarm
9
RS485 BUS
RS485 communications port for connection to an
ACC FLN channel
8
Siemens Building Technologies
Fire Safety & Security Products
02.2005
Содержание AFI5100
Страница 4: ...4 Siemens Building Technologies Fire Security Products 02 2005 ...
Страница 13: ......