QUICK REFERENCE GUIDE 

DT INSTALLATION PROCEDURE A FOR 

GCP 4000 DISPLAY MODULE A80407-01 

(AND EARLY -03) USING A COMPACT 

FLASH DEVICE

 

 

Document Number SIG-QG-09-02 

Version B.1 

The following procedure should be used when upgrading 
the Diagnostic Utility (DT) in a GCP 4000 Display Module, 
P/N 8000-80407-0001 and early versions of P/N 8000-
80407-0003 (see note below). 

 

NOTE 

If the A80407-03 Display Module is labeled 

DISPLAY 

II

, you  must use 

DT Installation Procedure B

 

(document No. SIG-QG-09-03) to install the DT 
software. 

 

INSTALLING THE DT IN GCP 4000 DISPLAY MODULE 
A80407-01 OR EARLY A80407-03 

 

To perform this procedure you will need a pre-
loaded Compact Flash device, Siemens part number 
Z224-9V244-A010, containing the latest DT software 
version  that is compatible with the currently 
installed MCF. In addition to the preloaded Compact 
Flash device you will need a PCMCIA adapter 
module to install the Compact Flash device in the 
Display Module. This adapter module can be 
purchased from Siemens  by ordering P/N  Z714-
02115-0000.  

 

NOTE 

Upgrading the DT Utility in the Display Module will 
NOT interfere with the safe operation of the 
highway crossing warning system. 
 

1.

 

Locate and remove the A80407 display module from 
the GCP 4000 chassis. 

 

2.

 

Locate the boot DIP switches on the top edge of the 
Display Module (accessible through the slot in the top 
of the Display Module case, figure #1). The Display 
Module boot DIP-switch normal positions are: switch 
1= OFF, switch 2 = ON. For Phase 1 stylus calibration, 

position both switches to the OFF position (see figure 
#2 below).

 

    #1

 

   #2

 

 

3.

 

Insert the Siemens provided Compact Flash memory 
device into the PC card adapter. Then install the 
adapter in the A80407 Display Module through the 
slot in the top of the Display Module case (figure #3).  
Reinstall the Display Module in the GCP 4000 chassis 
as shown in figure #4 below.  Apply power to the GCP 
4000 if not already powered up. 

#3

 

 

 
 
 
 
 
 
 
 
 
 

#4 

 

4.

 

With the use of the stylus, calibrate the display by 
tapping the +

 

sign as it appears on the display (figure 

#5).  At the end of this calibration process a 30 
second timer will run (figure #6). Tap the display one 
more time before this timer expires to save the new 
display module calibration settings.  

 

 

 

 

 

 

 

 

 

 

 

 

 

                           

#5   

 

                                #6

 

5.

 

The screen shown in figure #7 indicates the 
completion of Phase 1 and provides additional 
information in preparation for Phase 2.  Remove the 
A80407 Display Module from the 4000 chassis and 
then remove the PC card adapter and Compact Flash. 
Set both Display Module DIP switches back to the 
normal position: switch 

1 = OFF

 and switch 

2 = ON

.  

Reinstall the PC card adapter and Compact Flash in 
the A80407 Display Module.  Reinstall the Display 
Module in the GCP 4000 chassis. 

 

 

 

 

 

 

 

 

 

#7

 

 
 
 
 
 
 
 

#8

 

6.

 

After reinstalling the A80407 module in the GCP 4000, 
the display will execute its boot cycle.  After the 
completion of the boot up process the display will 
show a prompt asking if “you want to reformat the 
FlashFX Disk?”. Select 

Yes

 (figure #9). When the 

WARNING appears select 

OK

 (figure #10). 

 
 
 
 
 
 
 
 
 
 

#9

 

NOTE 

In the following figures the DT version number 
at the top of the screen and the OS Build 
number at the bottom will vary depending on 
the DT and OS software versions installed.

Normal position

ON

OFF

1

2

calibration position

ON

OFF

1

2

Copyright

© 

2008-2014 Siemens 

All

 

rights reserved

 