Installation and Wiring

 9510 and 9610 I/O Card

Page 2

Installation and Wiring

D

ANGER

During normal operation of the meter, hazardous voltages are present which can cause severe injury or
death. These voltages are present on the terminal strips of the device and throughout the connected
potential transformer (PT), current transformer (CT), status input, relay, and control power circuits. Only
qualified, properly trained personnel should perform installation and servicing.

The standard model I/O card has 8 digital inputs. Depending on what you ordered, 
the I/O card will also contain either 4 analog inputs, or 4 analog outputs, or both. 
Check the label on the I/O card for your I/O specifications.

AI4

AO4

AI3

A03

AI2

A02

AI1

AO1

Rear View of Meter

Analog connections from
external transducers
0 to 20 mA or 0 -1 mA

Analog Connections to
analog transducers
0 to 20mA: 500 Ohm load Max
-1 to 1mA: 10k Ohm load Max

Digital connections from
external relays or pulse counter
50 VDC Max

External Dry Contacts
(polarity for SSR
contacts shown)

AWG 12 to 14 (3.3 to 2.1 mm ) recommended; wire sizes will vary depending on application

2

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8

DICOM

AI1

+

-

AO1

OUTCOM

I/O C

ARD

Standard I/O Locations

Содержание 9510

Страница 1: ...arks are property of their respective owners Revision Date July 19 2004 9510 and 9610 I O Card This document describes how to install configure and verify the operation of the optional Input Output card I O card available for your 9510 9610 meter It supplements your meter s Installation Guide and User s Guide In This Document Installation and Wiring 2 Preparing the Meter for Installation 3 Install...

Страница 2: ... 8 digital inputs Depending on what you ordered the I O card will also contain either 4 analog inputs or 4 analog outputs or both Check the label on the I O card for your I O specifications AI4 AO4 AI3 A03 AI2 A02 AI1 AO1 Rear View of Meter Analog connections from external transducers 0 to 20 mA or 0 1 mA Analog Connections to analog transducers 0 to 20mA 500 Ohm load Max 1 to 1mA 10k Ohm load Max...

Страница 3: ...these steps to install the I O card 1 If present remove the plastic tab that seals the I O card s cover plate to the meter Use the Phillips screwdriver to remove the plate s two screws then remove the plate 2 Hold the I O card by the sides and slide it into the base unit with the component side facing up Slide the edge of the circuit board down the slots along each side of the chassis 3 Align the ...

Страница 4: ...O and Anlg I O WinPM Net Vista Diagram The meter s Vista screens have provisions for monitoring and altering the states of each I O port Testing Analog I O Operation Most analog devices such as dial type gauges connected to your analog input and output ports allow you to see whether the port is delivering current If your connected device cannot help you determine the port s operation follow these ...

Отзывы: