background image

INSTALLATION AND SERVICE INSTRUCTION

Siemens Industry, Inc.

 

 
 

UM91-HF 

 

Rev 6 

 

July 2012 

 

Supersedes Rev 5 

 

Model 91-HF 

Filter Regulator 

INTRODUCTION 

The Model 91-HF Filter Regulator removes impurities from an air supply and delivers 
an accurate output pressure.

 

 
 

SPECIFICATIONS 

Port Size 

(In, Out and Gauge) ¼" NPT 

Output Range 

0-120 psig (0-800 kPa) 

Max Supply Pressure 

150 psig (1034 kPa) 

Mounting 

Pipe or Through Body 

Flow Capacity 

22 SCFM (33.0 m

3

/hr) at 100 psig (700 kPa) supply with 20 psig (140 kPa) output 

Exhaust Capacity 

0.1 SCFM (0.17 m

3

/hr) with downstream pressure 5 psig (35 kPa) above set point 

Sensitivity 

1" (2.5 cm) of water 

Air Consumption 

Less than 5 SCFM (0.17 m

3

/hr) 

Effect of Supply 
Pressure Variation 

Less than 0.2 psig (1.4 kPa) for 25 psi (170 kPa) change 

Ambient Temp Limits 

0° to 160

°

F (-18° to 71

°

C) 

Weight 

1.6 lb (725 g) 

 
 

MATERIALS OF CONSTRUCTION 

Body 

Diecast Aluminum Alloy, Irridite and Baked Epoxy Finish 

Filter 

3 Micron Phenolic Impregnated Cellulose 

Diaphragm 

Nitrile Elastomer and Nylon Fabric 

Valve Seat Plug 

Nitrile Elastomer 

Additional Materials 

Brass, Zinc Plated Steel, Acetal 

 
 

INSTALLATION 

Install the regulator as close as possible to the instrument or tool it is to service.  For best filter drainage, orient the drain 
valve so that it is at the lowest point on the drip-well housing. The words “IN” and “OUT” are cast into the body to indicate 
the direction of flow. See Specifications for port size. Installation dimensions are shown on the next page.

 

 
 

 

Содержание 91-HF

Страница 1: ...sumption Less than 5 SCFM 0 17 m3 hr Effect of Supply Pressure Variation Less than 0 2 psig 1 4 kPa for 25 psi 170 kPa change Ambient Temp Limits 0 to 160 F 18 to 71 C Weight 1 6 lb 725 g MATERIALS OF CONSTRUCTION Body Diecast Aluminum Alloy Irridite and Baked Epoxy Finish Filter 3 Micron Phenolic Impregnated Cellulose Diaphragm Nitrile Elastomer and Nylon Fabric Valve Seat Plug Nitrile Elastomer ...

Страница 2: ... an appropriate certificate Non approved instruments are suitable for use with instrument air only Optional features and modifications such as tapped exhaust do not imply suitability for use with hazardous gases except as listed on an approval certificate CAUTION Synthetic compressor lubricants in the instrument air may cause deterioration of some components resulting in instrument failure See mat...

Страница 3: ...accumulated liquid 2 To clean the filter element a Shut off supply air WARNING Components can be ejected with great force if the instrument is disassembled while pressure is applied To avoid the risk of death or serious injury always turn off and vent supply pressure and any downstream pressure source when disassembling the instrument b Drain condensate c Remove four corner bolts from the bottom o...

Страница 4: ...to the Siemens Internet site and then click Process Instrumentation In the column to the right click Support Manuals In the column to the left select the product line e g Pressure or Temperature or Controllers to open navigation and search panes Note Navigation may change as the site evolves Warranty The sales contract contains the entire obligation of Siemens The warranty contained in the contrac...

Отзывы: