Outputs
Pulse output connection diagram for MAG 8000
MAG 8000 internal connection
87L166.10.10
①
②
③
Output A
Output B
Passive output - no polarization - open drain
External connection variant
87L167.10.10
4
5
6
6
④
⑤
⑥
Positive pulse logic
Negative pulse logic
Signal
Pulse output can be configured as volume, alarm or call-up, see Commissioning (Page 56).
Pulse output is not polarized and can be connected for positive or negative logic.
Pull up/down resistor (R) is selected in relation to power supply voltage (V) and with a max.
current (I) of 50 mA.
Note
Pulse output isolation
The MAG 8000 pulse output has a functional isolation only and must therefore be connected to
equipment complying with the Low Voltage Directive in order to be considered safe.