Technical data

7LF4 4210

7LF4 4211

7LF4 4212

Supply voltage:

230V 50/60Hz

120V 50/60Hz

24V AC/DC ±10%

Effective power consumption: Approx. 1 W
Contact rating:

1 changeover contact 16A 250V~µ cos 

ϕ

= 1

Parallel compensation:

60VA max. 7µF

Accuracy:

± 0,2 s / day under typical installation conditions
single strand 

multi strand

Terminal capacity:

1,5...4 mm

2

1,5...2,5 mm

2

Programmes :

56

Pulse start times:

84 (only if pulse function is activated)

Pulse duration:

1s … 59min 59s

Battery reserve:

6 years

Storage ambient:

-20°C to +60°C 

Working ambient:

-20°C to +55°C

General information

• Start-up: after applying the supply voltage, the time switch

starts automatically with the last selected function. The relay
position is set by the current program.

• Battery backup

- Backlighting not active
- Data key READ/WRITE only via the menu.

OK

Set language

Overview

Day, Time, Date

Switch status

Function

Receptacle for

data key

1800W    1800W      1800W       2300W      100W       100W        1800W      2300W   

+

+

Overview of programmed
switching times for the week.
Resolution 0.5h

MENU

OK

Select menu, back to main menu,
Hold down > 1s = operating display

Confirm selection or load parameters

Select menu options or set parameters

0

5

6

7

8

4

3

2

1

Safety notes

This product may be installed only by a qualified electrician. Non-compliance may result in a fire hazard or electric shocks. Before installation, read
the operating instructions and observe the product-specific requirements for the installation location. Use only original spare parts for repair and
maintenance. Unauthorised opening and repair by other persons will invalidate all claims for liability, replacement or warranty services.

7LF4 4210
7LF4 4211
7LF4 4212

1/4

GB

Содержание 7LF4 4210

Страница 1: ...nt program Battery backup Backlighting not active Data key READ WRITE only via the menu OK Set language Overview Day Time Date Switch status Function Receptacle for data key 1800W 1800W 1800W 2300W 100W 100W 1800W 2300W Overview of programmed switching times for the week Resolution 0 5h MENU OK Select menu back to main menu Hold down 1s operating display Confirm selection or load parameters Select...

Страница 2: ...liday program has run once it must be reactivated Summertime 1 hour Europe Factory set SPECIAL The switchover to from summertime can be freely programmed by entering a start date and end date and is then executed each year on the same day of the week e g Sunday A program consists of an ON time OFF time and associated ON and OFF days Programs with predefined on off days Mon to Sun Mon to Fri and Sa...

Страница 3: ...sting on the data key will be overwritten Load the programs from the data key to the time switch READ KEY Warning all programs already programmed in the time switch will be overwritten Displays the total relay ON time from 0 to 65535 h and the date of the last reset Function active the programmed switching cycles are shifted at random within the range of 30 minutes or 3 4 ...

Страница 4: ... duration Pulse start time activation Pulses are also started during power failures Aafter the power has been restored they are output for the remaining running time Overlapping pulses restart the pulse start time When switching from PASSIVE to ACTIVE the program memory is cleared 4 4 ...

Отзывы: