Figure 6-5
Schematic diagram: Connecting power cables
6.8.2
Procedure
To connect the power cables, proceed as follows:
1. Open the cabinet.
2. If there is a controller rack, swing it out of the way.
3. Remove or slide away the cover plate for the power cable entry.
4. Screw the PE protective conductor with an M12 screw at the locations
④
provided in the
cabinet to the appropriate connection with the ground symbol. Observe the torque of 50 Nm.
On this topic, take note of section "Connecting ground (Page 75)".
5. Screw the individual phases of the power cables
①
with the connections in the lower area
of the cabinet. To do this, follow the subsequent steps.
6. Insert the M12 screw into the corresponding terminal bar
②
.
7. Attach the cable lug.
8. Attach the nuts and, if necessary, the washers. Tighten the nuts with a torque of 50 Nm.
9. Expose the cable shield. Secure the cable on the cable support bar using cable clips
③
.
6.8.3
Shield connection
Only use shielded medium-voltage cables to reduce cable-conducted radio frequency
interference (RFI) and to achieve the appropriate EMC compatibility.
● The cable shield must be uninterrupted over the complete length of the cable and must
comprise non-magnetic material. Preferably use cables with foil-type shields.
● Do not connect other cable shields, power cables or control signals to the motor cable
shield. Powerful electrical interference and disturbances are induced in cables such as
these.
● For plants and systems distributed over a wide physical area, always use an equipotential
bonding conductor.
● Correctly connect armored cable using a cable gland. The cable armor must be connected
to the cable gland around its complete circumference. The gland itself must be in contact
with the gland plate around its complete circumference and must be connected to PE.
Electrical connection
6.8 Connecting power cables
SINAMICS PERFECT HARMONY GH150 6SL3825
Operating Instructions 05/2020
79
Содержание 6SL3825
Страница 2: ...19 06 2020 09 58 V14 00 ...
Страница 12: ...Table of contents SINAMICS PERFECT HARMONY GH150 6SL3825 12 Operating Instructions 05 2020 ...
Страница 128: ...Maintenance 9 7 Repair SINAMICS PERFECT HARMONY GH150 6SL3825 128 Operating Instructions 05 2020 ...
Страница 130: ...Spare parts SINAMICS PERFECT HARMONY GH150 6SL3825 130 Operating Instructions 05 2020 ...
Страница 134: ...Service Support SINAMICS PERFECT HARMONY GH150 6SL3825 134 Operating Instructions 05 2020 ...
Страница 140: ...Quality documents SINAMICS PERFECT HARMONY GH150 6SL3825 140 Operating Instructions 05 2020 ...
Страница 142: ...Additional documents SINAMICS PERFECT HARMONY GH150 6SL3825 142 Operating Instructions 05 2020 ...
Страница 145: ......
Страница 146: ...Further Information www siemens com LDA Siemens AG Large Drives Applications Vogelweiherstr 1 15 90441 NÜRNBERG GERMANY ...