Parameter settings
5.6 Parameters and commands of FB 45
SIMATIC RF170C
Operating Instructions, 02/2022, J31069-D0176-U001-A6-7618
39
5.6
Parameters and commands of FB 45
Parameters of FB 45
Assignment is made in UDT 10.
Table 5- 5
Parameters of FB 45
Address
Name
Permissible values
Comment
+0.0
ASM_address
256, 260, 264, 268,
...
Each RF170C occupies four bytes of
I/O in the I/O area of the control
unit
+2.0
ASM_channel
1, 2
+8.0
MDS_control
B#16#0, 1
0 = no presence check
1 = presence check
+9.0
ECC_mode
TRUE, FALSE
+9.1
RESET_long
TRUE, FALSE
TRUE,
if MOBY mode = 5 (MOBY U/D, RF300)
+10.0
MOBY_mode
B#16#1, 4, 5, 6, 7,
8, 9, A, B
Special features of the MOBY I dialog
(8):
•
Write/read device must be type
SLG4x.
•
The VMDS memory size is 16KB. The
INIT command for the VMDS must be
specified using 4000 hex.
+11.0
scanning_time
MOBY I:
B#16#00 ... FF
A value not equal to 00 is only
practical if MOBY_mode has been
parameterized accordingly.
MOBY D, RF300 reserved (00)
MOBY U:
B#16#00 ... C8
+12.0
option_1
B#16#00, 02, 04
+13.0
distance_limiting
MOBY U (normal
output power):
B#16#05, 0A, 0F, 14,
19, 1E, 23
MOBY U / D
MOBY U (reduced
output power):
B#16#85, 8A, 8F, 94,
99, 9E, A3
MOBY D, RF290R:
B#16#02 ... 28
RF380R:
B#16#02 ... 08
+14.0
multitag
B#16#1
MOBY U/D, RF300
+15.0
field_ON_control
MOBY U:
B#16#0, 1, 2, 3
MOBY U/D, RF300
MOBY D, RF300:
B#16#0
+16.0
field_ON_time
MOBY U:
B#16#00 ... FF
MOBY U/D
RF300 reserved (00)
MOBY D:
B#16#00, 01
You will find detailed information on the parameters of FB 45 in combination with the
RF620R/RF630R readers in the section “Parameter assignment > Parameter assignment
RF620R/RF630R with FB 45 > Input parameters" in the "Configuration Manual
RF620R/RF630R".