Connection
6.6 Replacing a CLP
SCALANCE W1788-x / W1748-1
72
Operating Instructions, 03/2022, C79000-G8976-C484-05
6.6
Replacing a CLP
Position
The PLUG slot is on the bottom of the device housing under a cover, see Reset button
(Page 19).
①
CLP
②
Slot cover
③
M3 screws (Torx T10)
Removing a CLP
Note
Loss of the configuration
The reset button is located directly beside the slot for the CLP. The reset button cannot
be used to remove the CLP.
If you press and hold down the reset button you reset all the settings of the device to the
factory defaults.
To remove a CLP from the device, follow the steps below:
1.
Turn off the power to the device.
2.
Loosen the screws M3
③
with a Torx screwdriver T10 and remove the slot cover
②
.
As an alternative, you can loosen only one of the screws
③
and swivel the slot cover
②
to the side.