5.9.1.5
Mode LED (SCALANCE X204RNA EEC (PRP/HSR))
The SCALANCE X204RNA EEC (PRP/HSR) has the labeling of both devices on its housing, in other
words, that of the SCALANCE X204RNA EEC (PRP) and the SCALANCE X204RNA EEC (HSR).
Depending on how you configure the SCALANCE X204RNA EEC (PRP/HSR), the labeling is valid
as described in the sections above.
The exception is the mode LED (third LED from the top):
• When the LED is lit, the SCALANCE X204RNA EEC (PRP/HSR) is in HSR mode. This means that
the right-hand labeling of the LED displays applies. The device behaves like a SCALANCE
X204RNA EEC (HSR).
• When the LED is not lit, the SCALANCE X204RNA EEC (PRP/HSR) is in PRP mode. This means
that the left-hand labeling of the LED displays applies. The device behaves like a SCALANCE
X204RNA EEC (PRP).
5.9.2
SCALANCE X-200RNA (HSR)
5.9.2.1
Fault LED
If the LED is lit red, a SCALANCE X-200RNA (HSR) has detected an error/fault.
At the same time, the signaling contact opens assuming that the response of the signaling
contact has not been configured differently.
The LED signals that the SCALANCE X-200RNA (HSR) can adopt the following statuses:
Device type SCALANCE
LED lit red
LED lit yellow
LED not lit
X204RNA (HSR)
1, 2, 3, 4, 5, 6
7
8
X204RNA EEC (HSR)
1, 3, 4, 5, 6
7
8
X204RNA EEC (PRP/HSR)
If configured as HSR device.
1, 3, 4, 5, 6
7
8
1. Link down event on a monitored port.
2. Failure of one of the two redundant power supplies.
3. C-PLUG error.
4. Device startup, the LED is lit for approx. 20 seconds.
5. Internal error.
6. A redundancy error has been detected (unexpected frames via HSR1, HSR2, P1/A or P2/B
ports).
7. Redundancy warning (incorrect LAN ID at P1/A or P2/B)
8. No problem has been detected by the SCALANCE X-200RNA (HSR).
5.9.2.2
Power LED
The LEDs signal the following statuses of the SCALANCE X-200RNA (HSR).
Device description
5.9 LEDs
SCALANCE X-200RNA
54
Operating Instructions, 04/2022, C79000-G8976-C342-07
Содержание 6GK5204-0BA00-2KB2
Страница 6: ...Table of contents SCALANCE X 200RNA 6 Operating Instructions 04 2022 C79000 G8976 C342 07 ...
Страница 14: ...Safety notices SCALANCE X 200RNA 14 Operating Instructions 04 2022 C79000 G8976 C342 07 ...
Страница 18: ...Security recommendations SCALANCE X 200RNA 18 Operating Instructions 04 2022 C79000 G8976 C342 07 ...
Страница 80: ...Connecting up 7 5 Grounding SCALANCE X 200RNA 80 Operating Instructions 04 2022 C79000 G8976 C342 07 ...
Страница 82: ...Maintenance and cleaning SCALANCE X 200RNA 82 Operating Instructions 04 2022 C79000 G8976 C342 07 ...
Страница 152: ...Technical specifications SCALANCE X 200RNA 152 Operating Instructions 04 2022 C79000 G8976 C342 07 ...