Diagnostics
7
7.1
LED displays
LED states in PROFINET mode
State
H1
SYNC
H2
FAULT
H4 PN
H5 IE
H3 PWR
PER *)
0 Device is switched off
Off
Off
Off
Off
Off
Off
1 Device is switched on and the in‐
ternal voltage is in the setpoint
range
Off
Off
Off
Off
On
N/A
2 Boot loader is started
Off
On
Off
Off
On
N/A
3 Linux is started
On
On
Off
Off
On
N/A
4 MCP software is running, no PN
communication
Off
Off
On
Off
On
1 Hz
5 MCP software is running, PN com‐
munication established, STOP
state
On
Off
On
Off
On
N/A
6 MCP software is running, PN com‐
munication established, RUN state
0.5 Hz
Off
On
Off
On
N/A
7 Error, e.g. incorrect configuration
or damaged USB peripheral
4 Hz
4 Hz
4 Hz
4 Hz
On
4 Hz
*) LEDs in peripheral devices (keyboards, Powerrides and user keys connected to the digital outputs)
LED states in IE mode
State
H1
SYNC
H2
FAULT
H4 PN
H5 IE
H3 PWR
PER *)
0 Device is switched off
Off
Off
Off
Off
Off
Off
1 Device is switched on and the in‐
ternal voltage is in the setpoint
range
Off
Off
Off
Off
On
N/A
2 Boot loader is started
Off
On
Off
Off
On
N/A
3 Linux is started
On
On
Off
Off
On
N/A
ONE MCP Part 1: MCP xxxx
Equipment Manual, 07/2020, A5E50324729B AA
53
Содержание 6FC5303-0AP0 Series
Страница 16: ...Description 2 3 Rating plate ONE MCP Part 1 MCP xxxx 16 Equipment Manual 07 2020 A5E50324729B AA ...
Страница 60: ...Technical data 8 3 Recycling and disposal ONE MCP Part 1 MCP xxxx 60 Equipment Manual 07 2020 A5E50324729B AA ...
Страница 64: ...Safety symbols ONE MCP Part 1 MCP xxxx 64 Equipment Manual 07 2020 A5E50324729B AA ...
Страница 66: ...Index ONE MCP Part 1 MCP xxxx 66 Equipment Manual 07 2020 A5E50324729B AA ...