• Using suitable cable clamps, connect the shield of the data line at the HMI device tightly to
a surface of the equipotential bonding rail.
• Route the equipotential-bonding cables and data cables parallel to each other and with a
minimum distance between them.
Note
Cable shields are not suitable for equipotential bonding. Only use the equipotential-bonding
cables required for this purpose. Ensure the cross-section of cables is sufficient when setting
up PROFINET networks. Otherwise there is a risk that interface blocks can become damaged
or destroyed.
5.1.2
Power supply
Connector designation:
X10
Connector type:
Terminal block, 4-pin contact strip
Total cable length:
10 m
Table 5-1
Pin assignment of connector X10
Pin
Name
Type
Meaning
1
P24
VI
Power supply 24 V DC (20.4 to 28.8 V)
2
-
NC
3
M
VO
Ground
4
M
VO
Ground
The 24 V DC is looped through via the connector. Pin1 is bridged with Pin2 and Pin3 is bridged
with Pin4 in the connector.
5.1.3
Ethernet ports X20
Connector designation:
X20 P1, X20 P2
Connector type:
Standard RJ45 socket
Max. data transmission rate:
10/100/1000 Mbit/s
Max. cable length:
100 m
Connector assignment:
Downlink (switch)
Connecting
5.1 interfaces
ONE MCP Part 1: MCP xxxx
34
Equipment Manual, 07/2020, A5E50324729B AA
Содержание 6FC5303-0AP0 Series
Страница 16: ...Description 2 3 Rating plate ONE MCP Part 1 MCP xxxx 16 Equipment Manual 07 2020 A5E50324729B AA ...
Страница 60: ...Technical data 8 3 Recycling and disposal ONE MCP Part 1 MCP xxxx 60 Equipment Manual 07 2020 A5E50324729B AA ...
Страница 64: ...Safety symbols ONE MCP Part 1 MCP xxxx 64 Equipment Manual 07 2020 A5E50324729B AA ...
Страница 66: ...Index ONE MCP Part 1 MCP xxxx 66 Equipment Manual 07 2020 A5E50324729B AA ...