8
Troubleshooting
A Listing of Errors
8
- 40
8. Troubleshooting
Check this section before concluding that your system is out of order.
8.1 A Listing of Errors
An error number contains information as listed below
OOOO
Table 8-1
A Listing of PERFIBUS
-
related Errors
Error No.
Causes and Solutions
H.8500
Error message
PROFIBUS Initial error
Cause
An error was detected in the hardware. The hardware may be at fault.
Solution
Replace the 2D
-TZ577 Card.
When replacing the card, contact its manufacturer for advice.
H.8501
Error message
PROFIBUS watch dog timer error
Cause
An error was detected in the hardware. The hardware may be at fault.
Solution
Replace the 2D
-TZ577 Card.
When replacing the card, contact its manufacturer for advice.
H.8502*
Error message
Plural PROFIBUS cards are set.
Cause
Only one card is accepted at any one time.
Solution
Install only one card.
H.8503*
Error message
PROFIBUS/CC
-Link cards are set.
Cause
Either PROFIBUS or CC
-Link card is accepted at any one time.
Solution
Install either a PROFIBUS card or a CC
-Link card.
H.8504
Error message
Either of the following messages is displayed:
(1)
PROFIBUS s
elf-check error n (n = 1~7).
(2)
PROFIBUS cannot self
-check
Cause
An error was detected in the hardware. The hardware may be at fault.
Solution
Replace the 2D
-TZ577 Card.
When replacing the card, contact its manufacturer for advice.
H.8505
Error message
Illegal param (PBMODE)
Cause
PBMODE parameters are not defined validly.
Solution
Correct PBMODE parameters. (0
-
normal, 2
- self-diagnosis)
H.8506
Error message
Exchange number cannot be set.
Cause
Power the system off and on again.
Solution
If the error recurs, contact the manufacturer for advice.
H.8507
Error message
Illegal param (PBMC)
Cause
PBMC parameters are not defined validly.
Solution
Correct PBMODE parameters. (1
-
Class 1, 2
-
Class 2)
·
An error marked with an asterisk
requires a power reset.
Take a corrective action which is stated in the "Solutions" section of the table below.
·
The type of error is indicated by a 4-digit number.
·
Errors are sorted into three classifications:
H: High-level error ·········· Servo mechanism is shut down.
L: Low-level error ············ Operation is suspended.