7
Procedure before Startup
Parameter Settings on the Side of Master Station
7
- 32
<Procedure for establishing 2D
-TZ577 Card slave parameters to Master Station>
[1]
Read GSD file stored in the CD-ROM supplied with the
2D
-TZ577 Card into a setting software
which is compatible with the Master Station.
[2]
Establish 2D
-TZ577 Card slave parameters, using the setting software.
[3]
Write the parameters into the Master Station.
For information about operating the setting software, refer to the instruction manual for the software that is used.
Setting
software
Master
Station
GSD file for
PROFIBUS
Interface Card
Write
Figure 7-
2
Conceptual illustration of GSD file being loaded
7.2.2
Slave Parameters
Parameters other than slave station numbers need be established as slave parameters for use in the Master
Station. The following table shows slave parameters for use in the 2D
-TZ577 Card.
Table 7-
2
A Listing of Slave Parameters
Item
Setting range
Description
Remark
Station number
(FDL Address)
0 to 125
Station number of 2D
-TZ577 Card is
defined.
If connection is made to
Class 1 Master, station
number need be set in the
robot parameter
"PBNUM" as well.
Communication
WDT
(Watchdog)
0/2 to 65000
Watchdog timer is defined.
0:
Communication WDT setting
is disabled.
2
-
65000:
Communication WDT setting
is enabled
(set value x 10msec).
-
Minimum response
time
(Min T_sdr)
1 to 255
A minimum response time lapsed until
response frames are permitted to be sent
to the Master Station is defined.
-
Group number
(Group identification
number)
Grp1 to Grp8
Group to which a station belongs is
defined.
Any station is allowed to belong to more
than one group (Grp 1 thru 8).
-
Data module settings
(Module
Configuration)
-
I/O
configuration information (defined in
"Cfg_Data" on the Master Station)
·
Types of settings: 48 patterns
·
Number of settings: 1 - 40
-
Data alignment
mode settings
(Data Alignment
Mode)
0
Position of data in the output receive
area/input send area of buffer memory
(defined in "User_Prm_Data" on the Master
Station)
0:
Lump alignment mode (LUMP mode)
*
This parameter takes on "0" only. No
change is permitted.
-