![Siemens 1PH818 Скачать руководство пользователя страница 102](http://html.mh-extra.com/html/siemens/1ph818/1ph818_operating-instructions-and-installation-instructions_378974102.webp)
WARNING
Machine damage
If the machine is not maintained it can suffer damage. This can cause faults which can result
in eventual or immediate death, serious injury or material damage.
Perform regular maintenance on the machine.
CAUTION
Dust disturbances when working with compressed air
When cleaning with compressed air, dust, metal chips, or cleaning agents can be whirled up.
Injuries can result.
When cleaning using compressed air, make sure you use suitable extraction equipment and
wear protective equipment (safety goggles, protective suit, etc.).
NOTICE
Damage to insulation
If metal swarf enters the winding head when cleaning with compressed air, this can damage
the insulation. Clearance and creepage distances can be undershot. This may cause damage
to the machine extending to total failure.
When cleaning with compressed air, ensure there is adequate extraction.
NOTICE
Machine damage caused by foreign bodies
Foreign bodies such as dirt, tools or loose components, such as screws etc., can be left by
accident inside the machine after maintenance is performed. These can cause short circuits,
reduce the performance of the cooling system or increase noise in operation. They can also
damage the machine.
● When carrying out maintenance work, make sure that no foreign bodies are left in or on
the machine.
● Securely attach all loose parts again once you have completed the maintenance
procedures.
● Carefully remove any dirt.
Note
Operating conditions and characteristics can vary widely. For this reason, only general
intervals for inspection and maintenance measures can be specified here.
9.2.1
Inspections in the event of faults
Natural disasters or unusual operating conditions, such as overloading or short circuit, are
faults that overload the machine electrically or mechanically.
Maintenance
9.2 Inspection and maintenance
SIMOTICS M-1PH8 1PH818., 1PH822.
102
Operating Instructions 07/2016
Содержание 1PH818
Страница 2: ...18 07 2016 14 04 V14 00 ...
Страница 12: ...Introduction SIMOTICS M 1PH8 1PH818 1PH822 12 Operating Instructions 07 2016 ...
Страница 28: ...Description SIMOTICS M 1PH8 1PH818 1PH822 28 Operating Instructions 07 2016 ...
Страница 48: ...Preparations for use 4 14 Converter operation SIMOTICS M 1PH8 1PH818 1PH822 48 Operating Instructions 07 2016 ...
Страница 82: ...Electrical connection 6 4 Auxiliary circuits SIMOTICS M 1PH8 1PH818 1PH822 82 Operating Instructions 07 2016 ...
Страница 100: ...Operation 8 10 Faults SIMOTICS M 1PH8 1PH818 1PH822 100 Operating Instructions 07 2016 ...
Страница 126: ...Spare parts 10 9 Speed encoder type 1PH818 1PH822 SIMOTICS M 1PH8 1PH818 1PH822 126 Operating Instructions 07 2016 ...
Страница 136: ...Quality documents SIMOTICS M 1PH8 1PH818 1PH822 136 Operating Instructions 07 2016 ...
Страница 163: ...D 3 Operating instructions of the EC external fan SIMOTICS M 1PH8 1PH818 1PH822 Operating Instructions 07 2016 163 ...
Страница 197: ...AA Manual STROMAG Break AC Manual Ziehl Abegg external fan ...
Страница 198: ...Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY www siemens com drives ...