Technical data and characteristics
6.1 Explanations
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
145
6.1.2
Explanations of the characteristic curves
Torque-speed diagram with field weakening
1
S1 duty
2
S1 duty with field weakening
3
S3 duty, cycle duration should not exceed 10% of the thermal time constant t
TH
4
S3 duty with field weakening, cycle duration should not exceed 10% of the thermal time constant t
TH
5
Voltage limit characteristic
6
Limit characteristic for S1 duty
7
Voltage limit characteristic with field weakening
8
Rated operating point at M
N
, n
N
, I
N
9
Operating point at M
MAX
, I
MAX
, n
MAX,MMAX
10
Torque M
0
at speed n = 1 rpm
Figure 6-5
Schematic description of the torque-speed diagram
The voltage induced in the motor winding increases as the speed increases. The difference
between the DC link voltage of the converter and the induced motor voltage can be used to
impress the current.
The torque must be reduced if the voltage limit of the infeed module is reached at speed n.
All operating points that can be achieved with the motor lie below the "voltage limiting
characteristic".
Содержание 1FW6092-2PC15-6AB3
Страница 1: ...1FW6 High Speed built in torque motors ...
Страница 2: ......
Страница 10: ...Introduction 1FW6 High Speed built in torque motors 8 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 140: ...Configuration 5 4 Mounting 1FW6 High Speed built in torque motors 138 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 298: ...Index 1FW6 High Speed built in torque motors 296 Configuration Manual 01 2020 6SN1197 0AE03 0BP3 ...
Страница 299: ......
Страница 300: ......