Information on the application of motors
7.6 Operation under vibrational or shock stress conditions
1FT7 Synchronous Motors
234
Configuration Manual, (PFT7S) 01/2009, 6SN1197-0AD13-0BP2
7.6
Operation under vibrational or shock stress conditions
In order to ensure problem-free operation and a long service life, the vibration values defined
in DIN ISO 10816 should not be exceeded.
Table 7- 4
Vibration values
Vibrational velocity V
rms
[mm/s] acc. to DIN
ISO 10816
Frequency f [Hz]
Acceleration a [m/s
2
]
4,5
10
0,4
4,5
250
10
Deviating from the specified standard, motors 1FT703⃞ to 1FT710⃞ may be operated with
higher loads, with the restriction that the service life will be reduced. In this case, only
operation outside the mounted natural frequency is permissible.
Peak acceleration
Axial 20 m/s
2
Radial 50 m/s
2
Shock duration
3 ms
3 ms
7.7
Drive coupling
Function description
In order to achieve optimum drive-out characteristics, ROTEX
Ⓡ
GS couplings supplied by
KTR should be used. The advantages of ROTEX
Ⓡ
GS couplings include:
●
2 to 4x torsional stiffness of a belt-driven gearbox
●
No intermeshing teeth (when compared to belt gearboxes)
●
Low moment of inertia
●
Good control behavior
They must be optimally harmonized with existing machine masses, the mounted mechanical
system, the machine stiffness, etc.
KTR provides assistance in the selection of the coupling, refer to http://www.ktr.com
Содержание 1FT7 Series
Страница 2: ......
Страница 12: ...Preface 1FT7 Synchronous Motors 12 Configuration Manual PFT7S 01 2009 6SN1197 0AD13 0BP2 ...
Страница 220: ...Motor components 5 4 Gearbox 1FT7 Synchronous Motors 220 Configuration Manual PFT7S 01 2009 6SN1197 0AD13 0BP2 ...
Страница 248: ...Appendix A 3 Suggestions corrections 1FT7 Synchronous Motors 248 Configuration Manual PFT7S 01 2009 6SN1197 0AD13 0BP2 ...
Страница 251: ......