IV430E REV. 00 Issued: 2020/06/03
User Manual SOLEIL SRT 1.5-6k 1ph
Pag. 32 of 56 +FR
3.5.4 AC Output (GRID) Connection
It is prohibited for several inverters to share a single AC switch.
It's forbidden to connect load between inverter and AC switch.
To ensure the inverter can be disconnected with load safely, we suggest equipping independent
dipolar breaker for each inverter to protect the inverter.
Table3-2
Recommended AC breaker specification
Model
Specification
SOLEIL SRT1.5K
20A
SOLEIL SRT2K
20A
SOLEIL SRT3K
25A
SOLEIL SRT3.6K
25A
SOLEIL SRT4K
32A
SOLEIL SRT4.6K
32A
SOLEIL SRT5K
32A
SOLEIL SRT6K
40A
During wiring, please pay attention to distinguish the AC live wire, neutral wire and grounding wire.
Step 1
Strip the insulation layer of AC live wire (L), neutral wire (N) and grounding wire (PE) for about
7mm, as shown in Figure3-21.