IV431E REV. 00 Issued: 2020/11/16 User Manual Soleil SPX 200K-250K
Pag. 67 of 76 +FR
Items
Min.
Typical Max.
Note
Relative humidity
0%
-
100%
-
Atmosphere (kPa)
70
106
-
-
Altitude (m)
0
-
4000
When the altitude exceeds
3000m, it is necessary to decrease
rated power to use.
Over-voltage category
Ċ
(DC)/
ċ
(AC)
Pollution degree
ċ
A.2 SPX225K
Items
Min.
Typical Max.
Illustration
Max. PV input voltage (V)
500
-
1500
-
MPPT working voltage with full
power (V)
860
-
1300
-
PV connected/ MPPT tracking
24/12
DC current of each route (A)
0
9
13
-
Max. input current - Imp (A)
30*12
PV short-circuit current
–
Isc (A) 50*12
PV input power (kW)
0
228
250.5
-
Startup voltage (V)
-
550
-
Grid features
Output power (kVA)
-
225
247.5
-
Rated grid voltage (V)
800(3P3W)
Grid voltage range (V)
720
800
880
Settable (If it is necessary to set
the parameter, please contact the
manufacturer.)
Содержание Soleil SPX 200K
Страница 1: ...Soleil SPX Series 200K 250K 3ph String PV Grid tied Inverter User Manual...
Страница 2: ......